Download Print this page

Toshiba Q9 Series Brochure & Specs page 7

Adjustable speed drives

Advertisement

Meets or Exceeds
Your Specifications
Input Voltage
HP Rating
1
Current Rating
4.8
Input Voltage
HP Rating
1
Current Rating
2.1
HP Rating
75
Current Rating
96
Input Voltage Range
Power Terminals
Input (L1/R, L2/S, L3/T), Output (T1/U, T2/V, T3/W), DCL (PO, PA), DC Bus (PA, PC)
Voltage Tolerance
±10%
Frequency Tolerance
±2%
Output Method
Sine Wave Pulse-Width Modulated System
Output Frequency Range
0 to 299 Hz
Constant Torque, Variable Torque, Automatic Torque Boost, Sensor-Less Vector Control (Speed), V/f Five-Point Setting,
V/Hz Pattern
Permanent Magnet Control, Auto Power-Saver
Overload Current Rating
100% Continuous; 110% for One Minute
Frequency Control
Rotary Encoder Integrated Into EOI, 0 to 10 VDC, ±10 VDC, 4 to 20 mA, Binary Input, Motor Operated Potentiometer
Frequency Accuracy
Analog Input: ±0.2% of Maximum Output Frequency; Digital Input: ±0.01% of ±0.022 Hz of Output Frequency
Frequency Resolution
Operation Panel: 0.01 Hz
Acceleration/Deceleration
0.1 to 6000 Seconds
Analog Inputs
Three: One Isolated Input Selectable Between 0 to 10 VDC/4 to 20 mA, One 0 to 10 VDC, and One ±10 VDC
Analog Outputs
Two Programmable to 57 Functions (One Switchable 0 to 10 VDC/0 to 20 mA, and One 0 to 1 mA)
Discrete Inputs
Eight Programmable to 41 Functions
Sink/Source Switching
Ability to Switch Between Sink Logic and Source Logic
Discrete Outputs
Three Programmable to 83 Functions (Two Form-A and One Form-C); Outputs Rated at 2 A/120 VAC, 2 A/30 VDC
PID (Set Point Control)
Adjustment of Proportional Gain, Integral Time, Differential Time, and Delay Filter
Braking Control
DC Braking, Over-Flux Braking
Communication Ports
Two-Wire/Four-Wire RS485
Communication Protocol
BACNet
Protective Functions
Overvoltage Stall, Overcurrent Stall, Critical (Skip) Frequencies, Ride-Through, Electronic Thermal Motor Protection
Interrupting Current Rating 100,000 AIC
Overcurrent, ASD Overheat, ASD Overload, Motor Overload, Overvoltage, Overtorque, Undercurrent, Ground Fault,
Faults
Communication Time-Out, Analog-Input Terminal Overvoltage, Emergency Stop, Input/Output Phase Loss, RAM/ROM
Error, Undervoltage
Retry
Ability to Reset Certain Faults Automatically; Programmable Up to 10 Retries
Restart
Ability to Detect Speed and Direction of Freewheeling Motor and Start into Motor Smoothly
EOI Display
Full-English Backlit LCD Display
Keys
LOCAL/REMOTE, ESC, RUN, MODE, STOP/RESET
Rotary Encoder
Encoder with Integrated Enter Key for Frequency and Parameter Adjustments
Monitoring
Monitors 19 Drive Conditions
Display Units
Programmed to Display Percentage or Volts/Amps
Temperature
-10˚ to 40˚C
Relative Humidity
Maximum 93% (Non-Condensing)
Altitude
1000 Meters or Less
3 to
230 V
1 to 2 HP
5 HP
5 to
460 V
1 to 3 HP
7.5 HP
Frame
2
3
Height (in.)
10.0
11.1
Width (in.)
5.1
6.1
Depth (in.)
6.0
6.5
Q9 Standard Specifications
2
3
5
7.5
7.8
11
17.5
25.3
2
3
5
7.5
3.4
4.8
7.6
11
100
125
150
200
124
156
180
240
Power Requirements
200 to 240 V, 50/60 Hz, Three-Phase
Control Specifications
®
, LonWorks
®
, Metasys N2
®
, Modbus RTU
Protection
Interface
Ambient Conditions
Q9 Dimensions
15 to
25 to
7.5 HP
10 HP
20 HP
30 HP
15 to
25 to
10 HP
40 HP
20 HP
30 HP
4
5A
5B
6
12.6
12.6
15.7
16.5
6.9
8.3
9.1
9.4
6.5
7.5
7.5
8.3
230 V
10
15
20
25
32.2
48.3
62.1
78.2
460 V, 50/60 Hz, Three-Phase
10
15
20
25
14
21
27
34
250
300
350
400
302
361
414
477
380 to 480 V, 50/60 Hz, Three-Phase
®
, APOGEE FLN
®
40 to
-
-
100 HP 125 HP
60 HP
50 to
75 to
-
150 HP 200 HP 250 HP
60 HP
125 HP
7A
7B
8
9B
21.7
21.7
24.8
36.2
9.4
12.6
12.6
12.2
8.3
9.5
11.4
14.6
30
40
50
60
92
120
150
177
30
40
50
60
40
52
65
77
-
-
-
300 to
400 HP
350 HP
10B
11B
12B
13A
40.2
46.9
46.9
46.9
13.8
13.0
16.9
23.0
14.6
14.6
14.6
14.6

Advertisement

loading