Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Installation Guide Preface Preface This guide describes the RUGGEDCOM RS920W. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
RUGGEDCOM RS920W Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
The RUGGEDCOM RS920W can also act as a wireless access point and can – in combination with an Ethernet over VDSL (EoVDSL) interface – aggregate many devices at a remote location back to the central control room using existing telephone grade cable (or other legacy serial cabling) at distances of up to 5 km (3 mi) at up to 35 Mbps (upstream and downstream).
• Terminal blocks for reliable maintenance free connections • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Section 1.2 Description The RUGGEDCOM RS920W features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Feature Highlights...
Section 2.6, “Connecting Power” Section 5.1, “Power Supply Specifications”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS920W: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. Required Tools and Materials...
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Section 2.3 Installing the Device in Hazardous Locations The RUGGEDCOM RS920W is designed to comply with the safety standards for Class I, Division 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
Section 2.4 Mounting the Device The RUGGEDCOM RS920W is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be installed on a 35 mm (1.4 in) DIN rail or affixed to a panel.
Section 2.4.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS920W can be equipped with panel adapters on the top and bottom of the chassis. The adapters allow the device to be attached to a panel using screws.
Control of the failsafe relay output is configurable through ROS. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for the RUGGEDCOM RS920W. To connect the failsafe alarm relay, do the following: Insert the failsafe alarm relay terminal block into the device and tighten the screws.
1. Normally Closed 2. Common 3. Normally Open Section 2.6 Connecting Power The RUGGEDCOM RS920W supports power input from a single high AC/DC or low DC power supply. IMPORTANT! • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
Page 21
RUGGEDCOM RS920W Chapter 2 Installation Guide Installing the Device CAUTION! Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the field, remove the braided ground cable connected to the surge ground terminal and chassis ground.
Section 2.6.2 Connecting Low DC Power RUGGEDCOM RS920W's equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply. To connect a low DC power supply to the device, do the following: NOTE Torque all terminal connections to 0.6 N·m (5 lbf-in).
Page 23
RUGGEDCOM RS920W Chapter 2 Installation Guide Installing the Device ± ± Figure 7: Terminal Block Wiring – Single DC Power Supply Inputs 1. Positive Terminal 2. Negative Terminal 3. Surge Ground Terminal 4. Braided Ground Cable Connect the negative wire from the power source to the negative terminal on the terminal block.
Page 24
Chapter 2 RUGGEDCOM RS920W Installing the Device Installation Guide ± ± ± ± Figure 8: Terminal Block Wiring – Dual DC Power Supply Inputs 1. Positive Terminal 2. Negative Terminal 3. Surge Ground Terminal 4. Braided Ground Cable Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
RUGGEDCOM RS920W Chapter 3 Installation Guide Device Management Device Management This section describes how to connect to and manage the device. CONTENTS • Section 3.1, “Connecting to the Device” • Section 3.2, “Configuring the Device” Section 3.1 Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces on the device.
Chapter 3 RUGGEDCOM RS920W Device Management Installation Guide Name Description Reserved (Do Not Connect) Transmit Data Receive Data Reserved (Do Not Connect) Signal Ground Reserved (Do Not Connect) Reserved (Do Not Connect) Figure 9: Serial DB9 Console Port Reserved (Do Not Connect) Reserved (Do Not Connect) Connected internally.
RUGGEDCOM RS920W Chapter 4 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RS920W can be equipped with various types of communication ports to enhance its abilities and performance. Figure 10: Port Assignment 1. Ports 1 and 2 2. Port 3 3. Port 9 Port Type...
Section 4.1 Wireless Ethernet Ports The RUGGEDCOM RS920W supports an optional set of IEEE 802.11 compliant wireless Ethernet ports for accessing a Wireless Local Area Network (WLAN). Depending on the options chosen, the device is permitted for use in either North America (US), the European Union (EU), Australia (AU), or India (IN).
RUGGEDCOM RS920W Chapter 4 Installation Guide Communication Ports 63 mW (18 dBm) 802.11g 48 Mbps Data Rate 40 mW (16 dBm) 802.11g 54 Mbps Data Rate Receiver Sensitivity At Radio 802.11b 11 Mb @ -88 dBm/With Antenna: 11 Mb @ -91 dBm At Radio 802.11g 54 Mb @ -74 dBm/With Antenna: 54 Mb @ -77 dBm...
Page 30
Master and pushed to the Slave. Data flowing from the Master to the Slave is designated downstream, while data flowing from the Slave to the Master is designated upstream. Siemens supports two types of EoVDSL: • Universal EoVDSL Universal EoVDSL ports are Master/Slave selectable and offer symmetric data rates (upstream and downstream) up to 35 Mbps.
Reserved (Do Not Connect) Section 4.3 Serial Ports The RUGGEDCOM RS920W supports DB9, RJ45 and ST (Straight Tip) fiber serial ports, all of which can be run in RS232, RS485 or RS422 mode. NOTE On power-up, all serial ports default to RS485 mode. Each port can be individually set to RS232, RS485 or RS422 mode through RUGGEDCOM ROS.
Page 32
Chapter 4 RUGGEDCOM RS920W Communication Ports Installation Guide Serial Ports...
0.24 A, 60 W 250 VAC 0.25 A, 62.5 W Section 5.3 Serial Port Specifications The following details the specifications for serial ports that can be ordered with the RUGGEDCOM RS920W. Copper Serial Ports Baud Rate 300 to 230 kbps Failsafe Alarm Relay Specifications...
Cable Size 50/125 or 62.5/125 Section 5.4 Operating Environment The RUGGEDCOM RS920W is rated to operate under the following environmental conditions. Ambient Operating Temperature -40 to 85 °C (-40 to 185 °F) Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
RUGGEDCOM RS920W Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RS920W device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
• Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health Section 6.1.4 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A)
Information Technology Equipment – Safety – Part 1: General Requirements Section 6.1.6 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Page 42
Chapter 6 RUGGEDCOM RS920W Certification Installation Guide Test Description Test Levels Severity Levels DC Power Ports ± 4 kV AC Power Ports ± 4 kV Earth ± 4 kV Ground Ports IEC 61000-4-5 Surge Signal Ports ± 4 kV Line-to-Ground ±...
Page 43
EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RS920W meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
Page 44
Chapter 6 RUGGEDCOM RS920W Certification Installation Guide EMC and Environmental Type Tests...