SUN2000-(196KTL-H3, 200KTL-H3, 215KTL-H3)
Seires
User Manual
Numbe
r of PV
Strings
11
13
Cable Specifications
Cable Type
PV cable that meets the
1500 V standard
Cables with high rigidity, such as armored cables, are not recommended, because
poor contact may be caused by the bending of cables.
Procedure
● Use the MC4 EVO2 PV connectors delivered with the inverter. If the PV
connectors are lost or damaged, purchase the connectors of the same model.
The device damage caused by incompatible PV connectors is beyond the
warranty scope.
● For models of the crimping tool and removal wrench, use the recommended
model or contact your Staubli dealer.
Step 1 Install the DC input power cable.
Issue 03 (2021-09-30)
Terminal Selection
PV1, PV2, PV3, PV4, PV5,
PV6, PV8, PV9, PV11, PV13
and PV14
PV1, PV2, PV3, PV4, PV5,
PV6, PV7, PV8, PV9, PV10,
PV11, PV13 and PV14
NO TE
If a SUN2000-196KTL-H3, SUN2000-200KTL-H3, or SUN2000-215KTL-H3 inverter is used,
do not connect each individual PV string in parallel or connect them using Y-branch
connectors. Otherwise, the inverter may be damaged.
NO TICE
NO TICE
Copyright © Huawei Technologies Co., Ltd.
Numb
er of
PV
Strings
12
14
Conductor Cross-
sectional Area (Unit:
2
mm
)
4–6
5 Electrical Connections
Terminal Selection
PV1, PV2, PV3, PV4, PV5, PV6,
PV8, PV9, PV10, PV11, PV13
and PV14
PV1, PV2, PV3, PV4, PV5, PV6,
PV7, PV8, PV9, PV10, PV11,
PV12, PV13 and PV14
Cable Outer Diameter
(Unit: mm)
4.7–6.4
44