INSTALLATION INSTRUCTIONS
Wall Brackets (cont)
Capacity (BTUh)
Bracket Style
07K/09K/12K
35N/35T/40N
15K/18K
50N/50T/70N
24K
70N/70T
30K/36K
100N
09K/12K/18K
35F/50F
18K/24K
70F
A. Prepare the Outdoor Unit for Installation
• Remove all packaging.
• Place supplied vibration pads onto outdoor unit's feet.
• Use team lift to place the unit on a solid foundation, 8" above the average snowfall.
Correct
Installation
Correct
Installation
Minimum height(H) should be higher than the highest
snowfall depth(D)(H=D+8")
16
50 F
Part Number
WJ65X23038/WJ65X23240/WJ65X23038
WJ65X23251/WJ65X23251/WJ65X23056
WJ65X23056/WJ65X23056
WJ65X22785
WJ65X27875/WJ65X25594
WJ65X26113
Step 3 - Installation of the Outdoor Unit
Drainage
4.88 in (124mm)
Ø 2 3/8 in (60mm)
2 5/32 in (55mm)
Factory Reference Number
10101275/10103071/10101275
10102598/10102598/10102740
10102740/10102740
10103059
10103620B/10104861
10104864
Incorrect
Installation
Drainage
Stand top is
covered
Incorrect
Installation
Unit may become covered in snow if the stand height is insufficient.
Drainage
clearance is too
small, causing
inadequate
drainage.