Entering Transducer and
Pipe Parameters
[CHx-PIPE Menu]
Accessing the PIPE
Submenu
2-4
Enter the transducer and pipe parameters via the
Figure A-1 on page A-1).
1. Press [ESC] , [ENTER] , [ESC] in sequence to enter the user program.
2. Press [ ] until PROG appears and press [ENTER] .
3. Press [ ] until the desired channel appears. Press [ENTER] at CH1
or CH2 .
4. Press [ ] until PIPE appears and press [ENTER] .
5. Do one of the following:
For standard transducers, use the arrow keys to enter the
transducer number. Press [
the desired location and press
decrease the number. Then press [ENTER] and proceed to the
next step.
For special transducers, proceed to the next section.
6. Go to one of the following sections:
Standard clamp-on transducers - proceed to Pipe Material on
page 2-6.
Standard wetted transducers - proceed to Pipe Outside
Diameter on page 2-7.
submenu (see
PIPE
]
and [ ] to move the cursor to
[ ] and [ ]
to increase or
Programming Site Data