Hitachi L300P Series Service Manual page 17

Hitachi inverter service manual
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

Function Mode
Code
Function name
C070
Data command
Communicating
C071
transmission speed
C072
Communication code
C073
Communication bit
C074
Communication parity
C075
Communication stop bit
Communication waiting
C078
time
C081
O adjustment
C082
OI adjustment
C083
O2 adjustment
C085
Thermistor adjustment
C086
AM offset adjustment
C087
AMI adjustment
C088
AMI offset adjustment
RUN time/Power ON time
b034
level
b035
Operation direction restrict
b036
Start reduced voltage
b037
Display selection
b080
AM adjustment
b081
FM adjustment
b082
Start frequency adjustment
b083
Carrier frequency setting
b084
Initialize mode
Country code for
b085
initialization
Frequency scalar
b086
conversion factor
b087
STOP key enable
Resume on FRS
b088
cancellation mode
b090
BRD usage ratio
b091
Stop mode selection
b092
Cooling fan control
b095
BRD selection
b096
BRD ON level
b098
Thermistor selection
b099
Thermistor error level
C061
Thermal warning level
C091
Debug mode selection
C101
UP/DWN selection
C102
Reset selection
Reset f frequency matching
C103
selection
C121
O zero adjustment
C122
OI zero adjustment
C123
O2 zero adjustment
s t
1
allowable motor
H003
selection
nd
2
allowable motor
H203
selection
s t
H004
1
motor pole selection
nd
H204
2
motor pole selection
s t
H006
1
stabilized factor
nd
H206
2
stabilized factor
Option1 operation selection
P001
on error
Option2 operation selection
P002
on error
Digital input option input
P031
mode selection(Acc/Dec)
DeviceNet running order of
P044
monitoring timer setting
Setting
in
action
P045
abnormal communication
Output assemble instance
P046
Number setting
Input
assemble
instance
P047
Number setting
Detect of idol mode for
P048
motion setting
Pole
setting
of
rotation
P049
speed
(Note) < > indicate the setting range of 90 to 132kW
(Note1) P044-P049 are displayed o n a 0.4- 7 5kW model.
L300P Setting range
02(operator)/03(RS485)/04(option1)/05(option2)
02(loop-back test)/03(2400bps)/04(4800bps)/
05(9600bps)/06(19200bps)
00(no parity name)/01(even parity)/02(odd parity)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)hr
00(Reverse is valid)/01(Only forward)/02(Only reverse)
00(Start reduced voltage time small)
-06(Start reduced voltage time large)
00(all display)/01(each function display)/
02(User setting / main setting)
0.5-12.0(kHz) Derating enable, <0.5-8.0kHz>
00(Trip history clear)/01(Data initialization)/
02(Trip history clear + data initialization)
00(Interior)/01(EC)/02(USA)
00(valid)/01(invalid)
00(0Hz start)/01(Start f-equaling)
00(deceleration stop)/01(Free-run stop)
00(Always ON)/01(ON during run, After power ON, then for 5 minutes
on stop is implied.)
00(invalid)/01(valid<invalid during stop>)/
02(valid<valid during stop>)
330-380/660-760(V)
00(invalid)/01(Positive temperature coefficient enable)/
02 (NTC enable)
0. – 9999. ( ohm)
00(No display)/01(Display)
00(No frequency data)/01(Keep frequency data)
00(Trip cancel during ON)/01(Trip cancel during OFF)/
02(Valid only during trip<Cancel during ON>)
00(0H z start)/01(Start f-equaling)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.20-90.0(kW) <0.20-160(kW)>
0.20-90.0(kW) <0.20-160(kW)>
00(TRP)/01(RUN)
00(TRP)/01(RUN)
00(operation)/01(option1)/02(option2)
of
00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop)
00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop)
0-38(even only)
1- 14
1. - 32.
7(7bit)/8(8bit)
1(bit)/2(bit)
0.-1000.(ms)
0.0 - 1000.
0.0 - 10.0(V)
0. - 255.
0. - 20.0( mA)
0. - 255.
0. - 255.
0.10-9.99(Hz)
0.1-99.9
0.0-100.0(%)
0. – 100. ( %)
2/4/6/8(pole)
2/4/6/8(pole)
0. - 255.
0. - 255.
0.00-99.99s
20,21,100
70,71,101
Initial data
N o t e
-FE/-FU/-FR
02
04
1.
7
00
1
0.
Setting on
forwarding
Setting on
forwarding
Setting on
forwarding
105.0
0.0
80
4.0
0.
00
06
00
180
60
0.50
3.0
00
01/02/00
1.0
00
00
0.0
00
00
00
360/720
00
3000.
80
00
00
00
00
Set on
forwarding
Set on
forwarding
Set on
forwarding
Set on
forwarding
Set on
forwarding
4
4
100.
100.
00
00
00
1.00
0.
21
71
01
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj300 series

Table of Contents