5-14. UNLEVELED RF OUTPUT ADJUSTMENTS (Cont'd)
3.
Press the [.~] step key to access each Cal Constant listed in the table below and preset the Cal
Constants to the value provided in the table. Be sure to terminate each entry by pressing [Hz].
If the A13 SYTM or the A24 Attenuator Driver/SRD Bias assembly has been replaced, preset the
4.
following potentiometers (pots) to the position stated (see Figure 5-41):
Center the following:
A24R3 (X2A)
A24R4 (X2B)
Set the following fully counter-clockwise:
A24R1 (OFF A)
A24R8 (X3C)
5.
If the A13 SYTM or the A28 SYTM Driver assembly has been replaced, preset the following pots to
the position stated (see Figure
Center:
A28R6 (OFST)
Set the following fully clockwise:
A28R13 (DRP)
Set the following fully counter-clockwise:
A28R19 (DYS)
A28R28 (BP3)
HP 8340B/41B
Cal
Value
Constant
3
100
100
4
5
100
6
100
7
100
8
100
9
1024
10
1024
11
1024
12
1024
50
0
51
0
A24R6 (X3A)
A24R7 (X3B)
A24R2 (OFF B)
A24R11 (X4C)
5-41):
A28R24 (BP2 FREQ)
A28R22 (DYO)
A28R82 (GAIN)
Cal
Value
Constant
52
0
53
0
71
1024
72
1024
73
1024
74
1024
75
25
76
1000
77
—25
78
25
80
0
A24R9 X4A)
A24R10 (X4B)
A24R5 (X2C)
A28R25 (BP3 FREQ)
A28R27 (BP2)
A28R99 (BP1)
A24R12 (MIN)
A28R88 (KICK)