Safety Precautions; General Disclaimer; Safety Disclaimer - LG LGES-5048 Quick Installation Manual

Hide thumbs Also See for LGES-5048:
Table of Contents

Advertisement

01

Safety Precautions

General Disclaimer

The information in this quick installation guide is subject to change due to product updates or
other reasons. This guide cannot replace the product labels or the safety precautions in the user
manual unless otherwise specified. All descriptions here are for guidance only.
Before installations, read through the quick installation guide and the user manual to learn about
the product and the precautions.
All installations should be performed by trained and knowledgeable technicians who are familiar
with local standards and safety regulations.
Check the deliverables for correct model, complete contents, and intact appearance. Contact the
manufacturer if any damage is found or any component is missing.
Use insulating tools and wear personal protective equipment when operating the equipment to
ensure personal safety. Wear anti-static gloves, clothes, and wrist strip when touching electron
devices to protect the inverter from damage. The manufacturer shall not be liable for any damage
caused by static electricity.
Strictly follow the installation, operation, and configuration instructions in this guide and user
manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not
follow the instructions. For more warranty details, please visit https
home-battery/product-info.lg

Safety Disclaimer

WARNING
DC Side
:
1. Ensure the component frames and the bracket system are securely grounded.
2. Connect the DC cables using the delivered PV connectors. The manufacturer shall not be liable
for the damage if other connectors are used.
3. Ensure the DC cables are connected tightly, securely, and correctly. Inappropriate wiring may
cause poor contacts or high impedances, and damage the inverter.
4. Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the
voltage should be under the max DC input voltage. The manufacturer shall not be liable for the
damage caused by reverse connection and extremely high voltage.
5. Ensure the minimum isolation resistance of the PV string to the ground exceeds 19.33kΩ to
avoid shock hazards.
6. Keep the battery off, and the inverter disconnects with PV panels and other AC power
before connecting the battery and the inverter. The rated voltage of the battery should meet
specifications of the inverter.
AC Side
:
1. The voltage and frequency at the connecting point should meet the on-grid requirements.
2. An additional protective device like the circuit breaker is recommended on the AC side.
Specification of the protective device should be at least 1.25 times the AC output rated current.
3. PE cable of the inverter must be connected firmly.
4. You are recommended to use copper cables as AC output cables. Contact the manufacturer if
you want to use other cables.