JP356SM
GE
30" Built-In CleanDesign Electric Cooktop
®
Dimensions and Installation Information (in inches)
Note: Check local codes for required
†
KW Rating
breaker size
240V
7.6
Important: Requires a 5" free area
208V
5.7
between the bottom of the cooktop to
any combustible material, i.e., shelving.
Breaker Size
Free area not required when installing
240V
40 Amps
wall oven underneath cooktop. Refer to
†
installation instructions. Requires a
208V
30 Amps
†
15" minimum from cooktop to adjacent
overhead cabinets. Units are furnished
with a 48" flexible armored cable.
Note: 30" Ribbon cooktops are approved for use over select GE
27"and GE 30" Single Wall Ovens and Warming Drawers. Refer to
cooktop and wall oven/warming drawer installation instructions
packed with product for current dimensional data. If installed
with a GE Profile
™
Telescopic Downdraft System, consult both
the cooktop and downdraft installation instructions packed with
product before installing. Cooktop gas/electric supply may need to
be re-routed to install downdraft. Consult cabinet
and countertop manufacturer's specs for flush mount installation
priorto install. Before installing, consult installation instructions
packed with product for current dimensional data.
For answers to your Monogram,
®
GE
appliance questions, visit our website at
®
ge.com or call GE Answer Center
800.626.2000.
GE Profile
™
or
service,
®
21-1/2
29-7/8
Cooktop
19-5/8
28-1/2
2-1/2**
Required
* Depth of unit at conduit connection location (rear) is
6-1/2" on models PP980/950 and 4-5/8" on models
PHP900/PP975/972/962/945/942/932/912,
JP655/356/346.
**Raised bull nose countertops may require up to
3/8" additional clearance to prevent interference
with curved front.
30_ss_cktp_install.eps
13" MAX.
depth
3-1/4*
30" MIN. to
unprotected
cabinet
15" MIN.
to cabinet
1-3/4" to
rear wall
1-1/2" MIN.
clearance to
side wall
from cut-out
Electrical junction box 16" MIN.
below countertop
Specification Revised 12/07
1-1/2" MIN.
clearance to
side wall
from cut-out
Cut should
not interfere
with cabinet
structure
at front
Listed by
Underwriters
Laboratories
321360