3 Specifications
Chapter 3: Specifications

3.1 General specifications

Item
Phase wire system
Rating
Voltage
single-phase
circuit
2-wire,
*
1
three-phase
3-wire
single-phase
3-wire
Current circuit
Frequency
Allowable tolerance of main module
(excluding current sensor) *
Measurable circuit count
Data update cycle
Response time
Backup for electric blackout
I/O occupation
* 1:110 V, 220 V direct connection is possible. For the circuit over this voltage, transformer (VT) is
necessary (Primary voltage of VT can be set up to 6600 V, and secondary voltage of VT can be set up
to 220V as optional setting). Star – delta connection and delta – star connection transformer instead of
VT cannot measure definitely to be out of phase. Please use a transformer of the same connection.
* 2:5 A primary current can be set when using the current sensor is as follows.
5A, 6A, 7.5A, 8A, 10A, 12A, 15A, 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A, 120A, 150A, 200A,
250A, 300A, 400A, 500A, 600A, 750A , 800A, 1000A, 1200A, 1500A, 1600A, 2000A, 2500A, 3000A,
4000A, 5000A, 6000A (Primary current of CT can be set up to 6000A in any . However, secondary
current of CT can not be set to other than 5A).
* 3:Please refer to 2 (1) as for the ratio error of the current sensor.
* 4:Demand shows the moving average of a set period.
* 5:Always accumulating the integrated values of Wh and varh. It can capture short-cycled load fluctuation.
single-phase 2-wire / single-phase 3-wire / three-phase 3-wire
110 V AC , 220 V AC
110 V AC (1 - 2 line, 2 - 3 line) 220 V AC (1 - 3 line)
50 A, 100 A, 250 A, 400 A, 600 A AC
(Current sensor is used. Each value refers to the current at the primary side of
current sensor.)
5 A AC
(Current sensor is used together with current transformer (CT), and the
primary-side current is configurable up to 6000 A.) *
50Hz to 60 Hz
Current
3
Current demand *
Voltage
Electric power
Electric power demand *
Reactive power
Frequency
Power factor
Electric energy
Reactive energy
1 circuit
5
250 ms *
2 seconds or less
Backup is made using nonvolatile memory.
(Stored items: settings, the max./min. values and time of occurrence, electric
energy (consumption, regenerated), reactive energy (consumption lag), and
periodic electric energy)
16 points (I/O assignment: intelligence 16 points)
Specifications
: ±1.0 % (100 % of the rating)
4
: ±1.0 % (100 % of the rating)
: ±1.0 % (100 % of the rating)
: ±1.0 % (100 % of the rating)
4
: ±1.0 % (100 % of the rating)
: ±1.0 % (100 % of the rating)
: ±1.0 % (45 Hz to 65 Hz range of the rating)
: ±3.0 % (against the electric angle 90°)
: ±2.0 %
(5 % to 100 % range of the rating, power factor = 1)
: ±2.5%
(10 % to 100 % range of the rating, power factor = 0)
3 - 1