REMOVE OF BODY VALVE ASS'Y AND WATER OUTLET
1. Remove the body in accordance with "REMOVE OF BODY".
2. Remove the reed SW. in accordance with "REMOVE OF REED SWITCH".
3. Detach 2 clamping springs holding the body valve ass'y and the water outlet to the heater tank ass'y.
4. Remove 2 screws holding the body valve ass'y.
5. Remove 2 screws holding the water outlet.
6. Now the body valve ass'y and the water outlet are free.
Clamping spring
Water outlet
Body valve ass'y
1. Remove the triac in accordance with "REMOVE OF TRIAC".
2. Remove the body valve ass'y and the water outlet in accordance with "REMOVE OF BODY VALVE ASS'Y
and WATER OUTLET".
3. Remove the screw to L-Wire Earth from heater tank ass'y.
4. Remove the screw holding cable tie from the heater tank support.
5. Remove 2 screws holding triac lead wire (brown) and thermostat lead wire (black) to the heater tank ass'y.
6. Remove 2 screws holding the thermostat to the heater tank ass'y.
7. Now the heater tank ass'y is free.
Cable tie
Screw
L-wire earth
Heater tank ass'y
Heater tank support
Screw
Screw
REMOVE OF HEATER TANK ASS'Y
Screw
Screw
Fig. 25
12
Heater tank
Back cover
Fig. 24
Triac lead wire brown
Brown lead wire
Black lead wire
Breaker lead
wire black
Thermostat lead
wire black
Screw
Thermostat
Back cover