Function Description - Beko BEKOMAT 16i CO Translation Of Original Installation And Operation Manual

Table of Contents

Advertisement

Original installation and operation manual

3.3 Function description

F
18
F
Illustration
44
18
44
Description / explanation
The condensate flows via the condensate 
inlet [F] into the BEKOMAT
the housing [18].
The filling level in the housing [18] is
continuously monitored by a capacitive
sensor in the sensor tube [44].
X1
Once the condensate has reached the
23
maximum fill level, the pilot valve [X1] is
activated using the controller.
The pilot valve [X1] activates, and the area
above the membrane [23] is depressurised.
D
The membrane [23] lifts off the valve seat 
and the excess pressure in the housing [18]
presses the condensate into the condensate
discharge [D].
When the sensor in the sensor tube [44]
X1
is no longer covered by condensate,
the controller of the pilot valve [X1]
23
activates and pressure builds up above the
membrane [23].
The membrane [23] is pressed against the
valve seat and the condensate discharge [D]
D
is sealed tightly.
The switching cycle starts again with the
feed of condensate.
BEKOMAT
16i CO
®
and collects in
®