Installation Guidelines - Bosch c-Si M 48 EU Installation And Operation Manual

Crystalline solar modules
Table of Contents

Advertisement

en

4 Installation guidelines

Important Notice!
 Definitely align the solar module so as to avoid a
shadowing effect (even to a temporary or partial
extent: e. g. due to roof dormers, trees), since this
can lead to damage in the solar modules (e. g. forma-
tion of „hot spots"), failure of the PV generator and
loss of output.
 The additional loads which arise by way of the weight
and the structural attachment of the PV system are to
be included in the structural analysis of the overall
construction.
 Verifications of stability, deflection and load parame-
ters are to be initiated by the constructor or the
operator of the system.
 Install the modules on a sufficiently-dimensioned,
load-bearing and permanently corrosion-resistant
substructure.
 Observe the specifications for mounting areas accor-
ding to Illustrations 1 and 2.
 Attachment with clamps on the narrow sides of the
solar module may not be performed.
 The attachment of the solar module can be perfor-
med with clamps (or as an alternative, directly on the
installation holes). When clamping systems are used,
the clamp surface per attachment point on the mo-
dule must amount to at least 400 mm².
 Position of the installation drill holes in accordance
with Illustrations 3 – 6
 Per module, four non-corrosive screws and nuts (and
grommets with min. 12 and max. 14 mm exterior
diameters) are to be used in accordance with Table 1.
Bosch Solar Module c-Si M 48 EU I Bosch Solar Module c-Si M 60 EU I Bosch Solar Module c-Si M 60 S EU I Bosch Solar Module c-Si P 60 EU   Bosch Solar Energy AG
 The modules must be attached flush to the substruc-
ture (without tension and deformation) at no less
than four points.
 The substructure and the solar module must have the
same heat-expansion coefficient (aluminum).
 Contact corrosion between the solar module and the
substructure is to be avoided when different materi-
als are used.
 Attach the solar modules so that they with-stand all
foreseeable loads and weather-induced influences.
 Only use non-corrosive screws for the installation.
 The solar module must be installed without mechani-
cal tension and (to compensate material expansion
due to temperature fluctuations) with a minimum gap
of 5 mm to the next module.
 Particularly in exposed locations, sufficient lightning
protection is recommended.
 Integration into existing lightning protection systems
must occur in observance of the valid regulations.
 Only install solar modules edgewise (or crosswise),
with the connector socket facing upward.
 In the course of elevation, it must be ensured that no
rainwater or condensation water can run in the direc-
tion of the cable screw connections on the connector
sockets.
 The solar module may not stand in tail water or con-
densation water.
Module manufacturer code
11, 13
14, 17, 23
Table 1: Permissible fastening screws for direct installation
Installation guidelines | 5
Screw diameter
M6
M8

Advertisement