Wall Mounted Type
ON/OFF
Model No.
1U12DR4EAA
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or
Repair the product or products dealt with in this service information by anyone else could result in serious injury or death
2016 (Qingdao Haier Air Conditioner General corp. , Ltd)
All rights reserved. Unauthorized copying and distribution is a violation of law
Haier Group
Version V1
Date 2016-11-07

Advertisement

Table of Contents
loading

Summary of Contents for Haier 1U12DR4EAA

  • Page 1 Repair the product or products dealt with in this service information by anyone else could result in serious injury or death 2016 (Qingdao Haier Air Conditioner General corp. , Ltd) All rights reserved. Unauthorized copying and distribution is a violation of law...
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com Contents Contents 1. Introduction ....................1 2. Specifications..................7 3. Piping diagrams ................... 9 4. Operation range ...................10 5. Printed Circuit Board Connector Wiring Diagram .........11 6. Dimensional drawings................12 7. Center of gravity ..................12 8.Service diagnosis ..................13 9 Performance Curves Diagram..
  • Page 3: Introduction

    All manuals and user guides at all-guides.com Introduction 1 Introduction 1.1 Model name explanation Apply toT1; 220~240V50HZ/1ph Heat pump & R410A refrigerant Version number District Platform of outdoor units: D (D platform) Nominal cooling capacity (12000BTU/h) Type of outdoor unit: U (normal type) The maximum combination number Domestic air conditioner...
  • Page 4 All manuals and user guides at all-guides.com...
  • Page 5 All manuals and user guides at all-guides.com...
  • Page 6 All manuals and user guides at all-guides.com...
  • Page 7 All manuals and user guides at all-guides.com...
  • Page 8 All manuals and user guides at all-guides.com...
  • Page 9: Specifications

    All manuals and user guides at all-guides.com Specifications 2 Specifications NOMINAL DISTRIBUTION SYSTEM VOLTAGE NOMINAL CAPACITY and NOMINAL INPUT cooling heating 3.31 3.57 Capacity rated Btu/h 11250 12150 Power Consumption(Rated) 1.03 0.99 ³ 1.6*10 ³ TECHNICAL SPECIFICATIONS-UNIT Dimensions H*W*D 660×275×540 Packaged H*W*D 802×373×595...
  • Page 10 All manuals and user guides at all-guides.com Specifications TECHNICAL SPECIFICATIONS-PARTS cooling heating Type Rotary Compressor Model 44A273BJ-FJKD Compressor Motor output 1120 Oil type NMOC Ze-Gles RB 68EP or equivalent Oil charge volume 0.32 Type Axial fan Motor output Air flow rate(high) m³/h 1500 Speed(high/low)
  • Page 11: Piping Diagrams

    All manuals and user guides at all-guides.com...
  • Page 12: Operation Range

    All manuals and user guides at all-guides.com...
  • Page 13: Printed Circuit Board Connector Wiring Diagram

    All manuals and user guides at all-guides.com Wiring Diagram 5. Printed Circuit Board Connector Wiring Diagram Wiring diagrams NOTE: 1.See above for wiring of heat pump type. 2.There are no dotted lines on cool only type.(marked with @ ),Wire is connected from 4 (marked with @ @ )on terminal block to 1.
  • Page 14: Dimensional Drawings

    All manuals and user guides at all-guides.com Dimensional drawings 6. Dimensional drawings unit:mm 7. Center of gravity unit:mm Domestic air conditioner...
  • Page 15: Service Diagnosis

    All manuals and user guides at all-guides.com Service diagnosis 8 Service Diagnosis 8 .1 Caution for Diagnosis The operation lamp flashes when any of the following errors is detected. 1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions, disabling equipment operation.
  • Page 16 All manuals and user guides at all-guides.com Service diagnosis 8.3 Problem Symptoms and Measures Symptom Check Item Details of Measure Check the power supply. Check to make sure that the rated voltage is supplied. None of the units operates Check the indoor PCB Check to make sure that the indoor PCB is broken Operation A power failure of 2 to 10 cycles can stop air conditioner...
  • Page 17 All manuals and user guides at all-guides.com Service diagnosis 8.4Codes and Description 8.4.1Problem Symptoms and Measures Symptom Check Item Details of Measure Check to make sure that the rated voltage is None of the units Check the power supply. supplied. operates Check the indoor PCB Check to make sure that the indoor PCB is broken...
  • Page 18 All manuals and user guides at all-guides.com Service diagnosis Check the connector connection. Correct the connection Is it normal? Thermistor resistance check Replace the thermistor Is it normal? Replace the indoor unit PCB Thermistor resistance check method: Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using tester. The relationship between normal temperature and resistance is shown in the value of indoor thermistor.
  • Page 19 All manuals and user guides at all-guides.com Service diagnosis 8.4.2.3 Indoor AC fan motor malfunction Indoor Display The rotation speed detected by the Hall IC during fan motor operation is used to determine Method of abnormal fan motor operation Malfunction Detection when the detected rotation feedback signal don’t received in 2 minutes Malfunction...
  • Page 20: Performance Curves Diagram

    All manuals and user guides at all-guides.com Performance Curves Diagram 9 Performance Curves Diagram 9.1 Cooling capacity-temperature curves Domestic air conditioner...
  • Page 21 All manuals and user guides at all-guides.com Performance Curves Diagram 9.2 heating capacity-temp.curves Domestic air conditioner...
  • Page 22 All manuals and user guides at all-guides.com Performance Curves Diagram 9.3 Cooling power consumption-temp.curves Domestic air conditioner...
  • Page 23 All manuals and user guides at all-guides.com Performance Curves Diagram 9.4 heating power consumption-temp.curves Domestic air conditioner...
  • Page 24 All manuals and user guides at all-guides.com Sincere Forever Haier Group Edited by : Wang Fang Haier Industrial Park, No.1, Haier Road Yang Xiaodong 266101, Qingdao, China_ Signed by : Yang Wenjun Http //www.haier.com Approved by: Wu Hongjin Domestic air conditioner...