Radnje koje je potrebno izvršiti kako bi se
napravila nova veza:
-
izaberite kabl za napajanje u skladu sa
preporukama u tabeli;
-
provucite kabl za napajanje kroz spojnicu;
-
uklonite 10 mm izolacije sa svakog
provodnika kabla za napajanje, uzimajući u obzir
neophodnu dužinu kabla za povezivanje na
priključni blok;
Note: make sure the terminal board screws
are tight.
Operations to be carried out to make a new
connection:
- Choose the power supply cable in accordance
with the recommendations in the table;
- Pass the power supply cable into the clamp;
- Strip the end of each
conductor of the supply
cord on a 10 mm length,
by taking in account the
requested length of the
cord for the connection to
the terminal block;
- A c c o r d i n g t o t h e
installation and with the
help of shunt bars which
you should have recovered
in the first operation, fix the
conductor as shown on the chart;
- Fix the cover;
- Screw the cable clamp.
ATTENTION:
If it should be necessary to replace the power
supply cord, connect the wire in accordance
with following colors/codes:
BLUE
BROWN
YELLOW-GREEN
SHUNT
Neutral
Live
( )
Earth
Connection to the terminals on the terminal
block
LAY OUT "1-3-5" LAY OUT "2-4"
MONOPHASE or TWO PHASES 220-240 V~
Cable
HO5V2V2F
THREE PHASES 220-240 V3~
Cable
HO5V2V2F
THREE PHASES 380-415 V2N~
Cable
HO5V2V2F
380-415V 2N ~
PE
L1
L2
220-240V ~
PE
L
L1 / L2 / L3 = Phase
GB 60
3x2,5 mm2
3x4 mm2
4x1,5 mm2
4x1,5 mm2
4x1,5 mm2
4x1,5 mm2
220-240V 3 ~
L3
PE
L1
220-240V 2 ~
L2
PE
N
Neutral
=
L2
L1
PE= Earth