Converting To Another Gas Type; Jet Table - Miele KM 2010 Operating And Installation Instructions

Table of Contents

Advertisement

Risk of explosion due to an in-
correct conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas in-
staller in strict accordance with cur-
rent local and national safety and
building regulations (GasSafe in the
UK). The installer is responsible for
ensuring that the appliance functions
correctly when installed.
When converting to another type of
gas, both the main and small jets
need to be changed.

Converting to another gas type

Jet table

The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Burner
Natural gas H
Small
Medium
Large
Wok
Liquid gas
Small
Medium
Large
Wok
Main jet
Small jet
0.69
0.39
0.95
0.42
1.10
0.54
1.35
0.80
0.50
0.27
0.65
0.32
0.78
0.40
0.98
0.54
59