Siemens SIMATIC NET SCALANCE X-000 Series Operating Instructions Manual

Siemens SIMATIC NET SCALANCE X-000 Series Operating Instructions Manual

Industrial ethernet switches

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
SCALANCE X-000
Operating Instructions
12/2018
C79000-G8976-C344-03
Introduction
Safety notices
Network topologies
Description of the device
Mounting
Connecting up
Maintenance and
troubleshooting
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE X-000 Series

  • Page 1 Introduction Safety notices Network topologies SIMATIC NET Description of the device Industrial Ethernet switches SCALANCE X-000 Mounting Connecting up Operating Instructions Maintenance and troubleshooting Technical specifications Dimension drawings Approvals 12/2018 C79000-G8976-C344-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................5 On the Operating Instructions....................5 Safety notices...............................9 Network topologies.............................11 Description of the device..........................13 Product overview........................13 Product properties and device view..................16 TP ports (twisted pair)......................17 LEDs............................19 Mounting..............................21 Safety notices for installation....................21 Types of installation.......................22 Installation on a DIN rail......................23 Installation on a standard rail....................24 Wall mounting........................25 Connecting up............................27...
  • Page 4 Table of contents SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 5: Introduction

    SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks (https:// support.automation.siemens.com/WW/view/en/1172207) Siemens SCALANCE (https://siemens.com/scalance) Further documentation In the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components", you will find information on other SIMATIC NET products that you can operate along with the devices of this product line in an Industrial Ethernet network.
  • Page 6 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 7 Feed under https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
  • Page 8 Introduction 1.1 On the Operating Instructions SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 9: Safety Notices

    Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
  • Page 10 Safety notices SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 11: Network Topologies

    Network topologies Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion. Which topologies can be implemented? Using the SCALANCE X-000 IE switches, you can implement star topologies. Note Keep to the maximum permitted cable lengths of the devices you are using. You will find the permitted cable lengths in the section "Technical specifications (Page 35)".
  • Page 12 Network topologies SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 13: Description Of The Device

    Description of the device What is possible? The SCALANCE X-000 IE switches allow the cost-effective installation of small Industrial Ethernet linear bus or star structures with switching functionality. The devices are designed for installation in a cabinet. Note It is not possible to use a SCALANCE X-000 in a redundant ring because it does not support redundancy.
  • Page 14 Description of the device 4.1 Product overview X005 X005TS X005EEC Standby redundancy IRT capability Fast learning Passive listening Log table SNTP + SICLOCK Cut Through Coated printed circuit boards Table 4-2 Overview of the connection options X005 X005TS X005EEC TP (RJ-45) Fast Ethernet 10 / 100 Mbps Unpacking and checking WARNING...
  • Page 15 Description of the device 4.1 Product overview Accessories Component Packaging unit Article number IE FC Stripping Tool 6GK1 901-1GA00 IE FC blade cassettes 6GK1 901-1GB00 IE FC TP standard cable GP 6XV1 840 2AH10 IE FC TP trailing cable 6XV1 840-3AH10 IE FC TP marine cable 6XV1 840-4AH10 IE FC TP trailing cable GP...
  • Page 16: Product Properties And Device View

    Description of the device 4.2 Product properties and device view Product properties and device view Possible attachments The SCALANCE X-000 has five RJ-45 jacks for connection of end devices or other network segments. Figure 4-1 SCALANCE X005 Note The SCALANCE X005 shown above has the same construction as the SCALANCE X005TS and SCALANCE X005EEC.
  • Page 17: Tp Ports (Twisted Pair)

    Description of the device 4.3 TP ports (twisted pair) TP ports (twisted pair) RJ-45 connector pinout With SCALANCE X-000, the twisted-pair ports are designed as RJ-45 jacks with MDI-X pin assignment (Medium Dependent Interface Autocrossover) of a network component. Pin number Assignment Pin 8 n.
  • Page 18 Description of the device 4.3 TP ports (twisted pair) Two components connected to a link segment can exchange information about the data transfer and can adapt their settings to each other. The mode with the highest possible speed is set. Note Setting ports with a fixed configuration Devices not supporting autonegotiation must be set permanently to 100 Mbps half duplex or...
  • Page 19: Leds

    Description of the device 4.4 LEDs There are two TP port groups: Group 1: P1 Group2: P2 to P5 Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to (corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2. The requirements for Environment A are met between ports of the same group, e.g.
  • Page 20 Description of the device 4.4 LEDs SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 21: Mounting

    Mounting Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If the device is installed in a cabinet, the inner temperature of the cabinet corresponds to the ambient temperature of the device. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING...
  • Page 22: Types Of Installation

    Mounting 5.2 Types of installation WARNING Requirements for the cabinet/enclosure The equipment shall be installed in a suitable enclosure that provides a degree of protection not less than IP54 in accordance with EN/IEC 60079-15. WARNING If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken.
  • Page 23: Installation On A Din Rail

    Mounting 5.3 Installation on a DIN rail Installation on a DIN rail Mounting To install the device on a 35 mm DIN rail complying with DIN EN 50022, follow the steps below: 1. Place the second housing guide of the device on the top edge of the DIN rail. 2.
  • Page 24: Installation On A Standard Rail

    Mounting 5.4 Installation on a standard rail 3. Release the DIN rail catch on the bottom of the device using a screwdriver. 4. Pull the lower part of the device away from the DIN rail. Figure 5-2 Removal from a 35 mm DIN rail Installation on a standard rail Installation on a SIMATIC S7-300 standard rail To install the device on an S7-300 standard rail, follow the steps below:...
  • Page 25: Wall Mounting

    Mounting 5.5 Wall mounting Figure 5-3 Installation on a SIMATIC S7-300 standard rail Removal To remove the device from the S7-300 standard rail, follow the steps below: 1. Disconnect all connected cables. 2. Release the screw on the bottom of the standard rail. 3.
  • Page 26 Mounting 5.5 Wall mounting WARNING Wall mounting outside of the control cabinet or housing does not fulfill the requirements of the FM approval. Note You must not install the device on a wall in hazardous areas. To mount the device on a wall, you require the following: ●...
  • Page 27: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals, or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70).
  • Page 28: Wiring Rules

    Connecting up 6.2 Wiring rules Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
  • Page 29: Power Supply

    Connecting up 6.3 Power supply Note Wire end ferrules Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp cross sections. Crimp shapes with wave-shaped profile are unsuitable. Power supply The power supply is connected using a 2-terminal plug-in block. The power supply is connected over a high resistance with the enclosure to allow an ungrounded set up.
  • Page 30: Grounding

    Connecting up 6.5 IE FC RJ-45 Plug 180 Grounding Installation on a DIN rail The device is grounded over the DIN rail. S7 standard rail The device is grounded over its rear panel and the neck of the screw. Wall mounting The device is grounded by the securing screw in the unpainted hole.
  • Page 31 Connecting up 6.5 IE FC RJ-45 Plug 180 Plugging in the IE FC RJ45 Plug 180 Plug the IE FC RJ45 Plug 180 into the twisted-pair port of the device until it locks in place. Figure 6-2 Plugging in the IE FC RJ45 Plug 180 With its tight fit and locking mechanism with the PROFINET-compliant male connector IE FC RJ45 Plug 180, the securing collar on the TP port of the device ensures a rugged node attachment that provides strain and bending relief for the RJ-45 jack.
  • Page 32 Connecting up 6.5 IE FC RJ-45 Plug 180 SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 33: Maintenance And Troubleshooting

    30 minutes before turning it on again. Device defective If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible. SCALANCE X-000...
  • Page 34 Maintenance and troubleshooting SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 35: Technical Specifications

    Technical specifications Note Note the article number in the technical specifications. The following technical specifications apply to the following devices: Device Article number SCALANCE X005 6GK5 005-0BA00-1AA3 SCALANCE X005TS 6GK5 005-0BA00-1CA3 Note Unless mentioned otherwise, the technical specifications in the following table relate to the SCALANCE X005 and SCALANCE X005TS.
  • Page 36 Technical specifications Technical specifications Ambient temperature During operation ● SCALANCE X005 ● 0 ℃ to +65 ℃ ● SCALANCE X005TS ● -40 ℃ to +75 ℃ During storage -40 ℃ to +80 ℃ During transportation -40 ℃ to +80 ℃ Relative humidity During operation ≤...
  • Page 37 Technical specifications Note The number of connected SCALANCE X Industrial Ethernet Switches influences the frame propagation time. When a frame passes through the SCALANCE X005 or SCALANCE X005TS, it is delayed by the store and forward function of the switch: ●...
  • Page 38 Technical specifications Technical specifications Ambient temperature During operation -40 ℃ to +75 ℃ During storage -40 ℃ to +80 ℃ During transportation -40 ℃ to +80 ℃ Relative humidity During operation ≤ 95 % no condensation Operating altitude During operation ≤...
  • Page 39 Technical specifications Note The number of connected SCALANCE X Industrial Ethernet Switches influences the frame propagation time. When a frame passes through the SCALANCE X005, it is delayed by the store and forward function of the switch: ● with a 64 byte frame length by approx. 10 µs (at 100 Mbps) ●...
  • Page 40 Technical specifications SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 41: Dimension Drawings

    Dimension drawings Figure 9-1 Dimension drawing, rear of the SCALANCE X-000 SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 42 Dimension drawings Figure 9-2 Dimension drawing, side view of SCALANCE X-000 SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 43: Approvals

    Unless mentioned otherwise, the following approvals apply to all variants of the SCALANCE X-000. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 44 "SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document ● on the data medium that ships with some devices. ● on the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013). Enter the document identification number C234 as the search term.
  • Page 45 Approvals The SIMATIC NET products described in these operating instructions meet the requirements of the EU directive 2014/34/EU "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres". Note Type of protection of the device The devices are approved for various types of protection. You can find the type of protection of your device and the ATEX certificate number on the nameplate.
  • Page 46 Approvals The following types of protection are possible: ● nA IECEx classification: Ex nA IIC T4 Gc Certificate no.: DEK 14.0025X The products meet the requirements of the following standards: – IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") –...
  • Page 47 Approvals The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 Ta: -40 ...
  • Page 48 Approvals EC directive The IE switches SCALANCE X005TS and SCALANCE X005EEC meet the requirements of the directive 72/245/EWG, version 2006/96/EC "Electromagnetic Compatibility". Railway approval The IE switches SCALANCE X005TS and SCALANCE X005EEC meet the requirements of the following standard: ● EN 50155 "Railway applications - Electronic equipment used on rolling stock". Note When used on railway stock, a stabilized power supply must be used to comply with EN50155.
  • Page 49 ● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) ● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) ● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/...
  • Page 50 Approvals Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. SCALANCE X-000 Operating Instructions, 12/2018, C79000-G8976-C344-03...
  • Page 51: Index

    Index Plugging in, 31 Pulling, 31 Installation Types of installation, 22 Accessories, 15 Insulation between the TP ports, 18 Approvals, 43, 47, 48, 49 Article number, 5 Auto polarity exchange, 18 Autonegotiation, 17 LEDs Port LEDs, 19 Power LED, 19 CE mark, 43 Components of the product, 14 MDI / MDI-X autocrossover function, 18...
  • Page 52 Index Safety notices for installation, 21 general, 9 Use in hazardous areas, 9, 21, 27 when connecting up, 27 SIMATIC NET glossary, 6 SIMATIC NET manual, 6 Switching properties, 36, 38 System manual, 6, 49 Technical specifications Connector, 35, 37 Design, dimensions and weight, 36, 38 Electrical data, 35, 37 Permitted ambient conditions, 35, 37...

Table of Contents