11.5 Heating capacity-temperature curves
outdoor temp.
DB/WB
-15℃
-10℃
-7/-8℃
2/1℃
7/6℃
12/11℃
18/16℃
24/20℃
10000
9000
8000
7000
6000
5000
4000
3000
performance curves
heating capacity and indoor/outdoor temp.table
10℃
5194
6526
7920
9780
9629
9417
7209
5941
heating capacity and indoor/outdoor temp.curves
outdoor tempe.(DB/WB)
indoor temp.(humidity 46%)
20℃
4686
5877
7181
8722
8477
8268
6537
5252
49
Performance and curves diagrams
27℃
4190
5158
6289
7663
7481
6892
5727
4698