_________________________________________________________________________________________________________
●
start_bs.sh – This is the file the base station uses when it's initially turned on. This will be
custom tailored by Siemens based on each customer's requirements. Changes should be
coordinated with Siemens.
●
ms_config.xml – This is the configuration file for the RS. This can be a single file or a symbolic
(pointer file) that points to the file that contains the configuration information for
link file
the remote station. It contains the IP configuration, system information which includes
the channel bandwidth, the RF information which includes TX/RX frequency, and
many other configuration parameters. These configuration parameters, their
definitions, and possible values can be found in the "BS5000 and Cobalt-Plus
Parameter Configuration Manual" for your software version. As a note, many
parameters in this file are interrelated and should not be changed without advanced
knowledge of the system. Parameters that can be changed are listed below:
○
IP CONFIGURATION (IP address, Netmask, Gateway, etc.)
○
UL/DL Frequency
○
RX_Gain
○
Sub-channel bitmap
●
snmpd.conf – snmpd configuration information
5.2.12 Remote Radio Configuration Overview
5.2.12.1.1
Cobalt Remote Software Configuration for the Airlink Venus Radio
This section describes the key configuration elements for the Cobalt remote software on a per
file basis. Cobalt remote software runs on the Airlink Venus remote radio. Be aware that the
configuration files contain many other parameters which should not be modified.
COM-00-21-04
Version No.: A.1
5-11
CONFIGURATION