Heat Dissipation Requirements - ABB ACS 600 Hardware Manual

Ac drives us supplement
Hide thumbs Also See for ACS 600:
Table of Contents

Advertisement

Appendix A – ACS/ACC 600 Technical Data
Heat DIssipation
Requirements
A-12
ACx 601/4/7 drives are self-cooled. The table below gives the heat
dissipated into the hot air exhausted from the drives. If the drives are
installed in a confined space, the heat must be removed from the area
by ventilation or air conditioning equipment.
ACx 600 Type Code
ACx 601-0003-2
ACx 601-0005-2
ACx 601-0006-2
ACx 601-0009-2
ACx 601-0011-2
ACx 601-0016-2
ACx 601-0020-2
ACx 601-0025-2
ACx 601-0030-2
ACx 601-0040-2
ACx 601-0050-2
ACx 601-0060-2
ACx 601-0070-2
ACx 601-0080-2
ACx 601-0100-2
ACx 604/7-0120-2
ACx 604/7-0140-2
ACx 604/7-0170-2
ACx 601-0006-4
ACx 601-0009-4
ACx 601-0011-4
ACx 601-0016-4
ACx 601-0020-4
ACx 601-0025-4
ACx 601-0030-4
ACx 601-0040-4
ACx 601-0050-4
ACx 601-0060-4
ACx 601-0070-4
ACx 601-0100-4
ACx 601-0120-4
ACx 601-0140-4
ACx 604/7-0120-4
ACx 604/7-0140-4
ACx 604/7-0170-4
ACx 604/7-0210-4
ACx 604/7-0260-4
ACx 604/7-0320-4
ACx 604/7-0400-4
ACx 604/7-0490-5
ACx 604/7-0610-5
ACx 604/7-0760-5
Heat Dissipation
Watts
BTU/Hr
112
380
156
530
182
620
217
740
370
1265
540
1840
620
2120
1000
3400
1120
3800
1480
5100
1880
6400
2185
7500
2950
10100
3200
10900
4300
14700
6300
21500
7800
26600
9600
32800
100
341
130
444
170
581
240
820
320
1093
460
1571
620
2117
760
2596
920
3142
1130
3859
1530
5225
1840
6284
2250
7684
2700
9221
2300
7848
2800
9551
3300
11260
4000
13650
5000
17061
6300
21500
7900
26956
10000
34121
12500
42652
12500
53912