Failure Code [Ca132] Throttle Sensor Low Error - Komatsu PC88MR-10 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

Failure code [CA132] Throttle Sensor Low Error

Action level
Failure code
L03
CA132
Detail of
Low voltage appears in signal circuit of fuel dial sensor.
failure
Runs engine with signal voltage of fuel dial as fixed value (as if fuel dial is at the half
Action of
position)
controller
Problem on
Engine speed cannot be controlled by using fuel control dial.
machine
Signal voltage from fuel control dial can be checked with monitoring function.
Related
(Code: 03000 "Fuel Dial Sensor Volt")
information
Method of reproducing failure code: Turn starting switch to ON position.
No.
Cause
Defective wiring harness
1
connector
Defective throttle sensor
2
power supply system
Defective throttle sensor (fuel
3
dial)
Open or short circuit in wiring
4
harness
Open circuit in wiring harness
5
(wire breakage or defective
contact of connector)
Short circuit in wiring harness
6
Ground fault in wiring harness
7
(contact with ground circuit)
PC88MR-10
Throttle Sensor Low Error
Failure
(Engine controller system)
Procedure, measuring location, criteria and remarks
1. See descriptions of wiring harness and connectors in "c: Electrical
equipment" in "Checks before troubleshooting" of "Related
information on troubleshooting", and check it.
2. Turn starting switch to ON position.
If this failure code is not displayed, wiring harness connector is
defective.
a If this failure code is displayed, perform following checks.
If failure code [CA2186] is also displayed, perform troubleshooting for it
first.
1. Turn starting switch to OFF position.
2. Disconnect connector P20, and connect T-adapter to male side.
Between P20 (male) (1) and (3)
Between P20 (male) (2) and (3)
Resistance
Between P20 (male) (1) and (2)
1. Turn starting switch to OFF position.
2. Disconnect connector CE03, and connect T-adapter to female side.
Between CE03 (female) (41) and (42)
Resistance
Between CE03 (female) (41) and (51)
a If no failure is found by check on cause 4, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connector CE03 and P20, and connect T-adapter to
each female side.
Between CE03 (female) (42) and P20
(female) (1)
Between CE03 (female) (51) and P20
Resistance
(female) (2)
Between CE03 (female) (41) and P20
(female) (3)
a If no failure is found by check on cause 4, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors CE03 and P20, and connect T-adapter to
either female side.
Between CE03 (female) (51) and (41), or
Resistance
between P20 (female) (2) and (3)
1. Turn starting switch to OFF position.
2. Disconnect connectors CE03 and P20, and connect T-adapter to
either female side.
Between ground and CE03 (female) (51) or
Resistance
P20 (female) (2)
40 Troubleshooting
Troubleshooting by failure code (Display of code)
(PC88MR-CA132-400-A-Z0-A)
4.0 to 6.0 kz
3 to 7 kz
3 to 7 kz
4.0 to 6.0 kz
3 to 7 kz
Max. 1 z
Max. 1 z
Max. 1 z
Min. 1 Mz
Min. 1 Mz
40-135