Sb, pulse transformer loosens
Hide thumbs Also See for DXR 140:

Advertisement

SOLUTION/IMPROVEMENT
Torx screws (T10)
• strong thread-locking compound (e.g. Loctite 2701).
• torqued by 0.6Nm.
Transformer brackets
• further milled in the bolt head area.
AFFECTED UNITS
S/N's DXR140xx0122-140xx0169
S/N's DXR250xx0033-250xx0039
S/N's DXR270xx0016-270xx0032
S/N's DXR300xx0021-300xx0048
S/N's DXR310xx0114-310xx0133
CORRECTIVE ACTION
Remove the Pulse transformer from the electrical cabinet; untighten the four T10 torx screws
which fixate the transformer to its two brackets. Then carry out following service actions:
• Mill/smoothen down the bolt head area on the two transformer brackets with a suitable file,
or simply replace the two brackets.
• Apply strong thread-locking compound on bolt threads (e.g. Loctite 2701).
• Re-tighten the four screws with 0.6Nm.
According to the procedure when/during:
• A scheduled service interval (100, 250, 500 or 1000 hour service).
• A customer complaint is noted related to described symptom/description.
or
• Any given occasion.
Strive to be pro-active!
PROCEDURE
Tools required: T-handle Allen key 3mm (min length160mm) & small scale torque wrench.
Remove the Pulse transformer according to the DXR 140/2xx/3xx workshop manual.
PARTS INFORMATION
Article #
Quantity
505 52 74-01
581 28 66-01
WARRANTY INFORMATION
The normal warranty policy applies.
Name
1
Transformer
2
Brackets
B1400033