Reinstate Panasonic AccuPulse Tools On Applications
1. Look Up Application Setting On Worksheet
Worksheet – Look up the application information on the "Panasonic Assembly Tool Set Up Worksheet".
2. Set Up Tool
Obtain Tool & Attachments – Obtain the tool, extensions and sockets for the application.
Program The Tool – Referring to the worksheet, program the tool to the same settings as recorded
previously confirming the Flush Point (L1-L7) & Program Setting (1-40)
3. Verify The Tool In The Calibration Lab – Update Worksheet
Set Up Transducer – Set up the Analyzer/Software per the settings recorded in the worksheet.
Adjust Simulator – Adjust the Joint Simulator per the recorded washer thickness in the worksheet.
Transducer – Warm up the Joint Simulator and Tool before testing. Run 10 cycles on the joint simulator
to get the components warmed up and grease moving.
Run The Tool – Run the tool on the Transducer with the Joint Simulator.
4. Run The Tool On The Application – Update Worksheet
Run The Tool - Run the tool on the application and be sure to hold the trigger until the tool shuts off.
Audit The Fastener - Conduct a static/residual audit of the fastener to verify accuracy.
Adjust Torque - If the torque is out of specification, adjust the tool's Program Setting (1-40) to increase
or decrease the torque until the residual audit is within specification.
5. Record / Tool History
Worksheet – Update the worksheet with the above information if any changes were made to the tool,
settings or attachments.
Wait 10 seconds in between rundowns.
If unable to achieve the required specifications, double check the tools set up (settings &
attachments) for any inconsistences.
Panasonic Assembly
Tools Set Up Worksheet
Panasonic Life Solutions Company of America Assembly Tools Division
2 Riverfront Plaza 5
th
Floor Newark, NJ 07102
www.panasonic.com/assemblytools