Page 1
INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LSES302S LSRE307S www.lge.com P/No.: MFL57205803...
Part 1 SAFETY BEFORE YOU BEGIN Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. IMPORTANT SAFETY INSTRUCTIONS Safety Glasses Read and follow all instructions before using your oven to prevent the risk of fire, electric shock, personal injury, or damage when using the range.
Page 3
Part 1 SAFETY Safety Glasses Tape Measure PREPARE TO INSTALL THE RANGE WARNING Pencil Gloves Safety Glasses TOOLS NEEDED • The information in this manual Tape Measure should be followed exactly. Safety Glasses - A fire or electrical shock may result causing property damage, personal injury or death.
Part 2 PREPARE TO INSTALL THE RANGE INSTALLATION DRAWINGS (LSRE Series only) NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR. CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. Safety Glasses For installation in CANADA, a Free-standing range is not to be installed closer than (12mm) from any adjacent surface.
Page 5
Part 2 PREPARE TO INSTALL THE RANGE INSTALLATION DRAWINGS (LSES Series only) NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR. CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. Safety Glasses For installation in CANADA, a Free-standing range is not to be installed closer than (12mm) from any adjacent surface.
Part 3 ELECTRICAL CONNECTIONS ELECTRICAL CONNECTION CONNECT RANGE CORD REQUIREMENTS The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block This appliance must be installed and grounded on a will then be accessible. branch circuit by a qualified technician in accordance with the National Electrical code ANSI/NFPA NO.
Part 3 ELECTRICAL CONNECTIONS Safety Glasses 3-wire connection with a power supply cord Tape Measure WARNING Pencil Gloves • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block.
Part 3 ELECTRICAL CONNECTIONS Safety Glasses 4-wire connection with a power supply cord 3-wire connection: conduit Tape Measure Install the conduit as follows: WARNING Pencil Gloves Remove the Conduit connection plate from the rear of • Only a 4-conductor power-supply cord kit drawer body and rotate it as shown in Figure 5.
Page 9
Part 3 ELECTRICAL CONNECTIONS 4-wire connection: conduit 1. Follow the instructions under “Install the conduit as 4-wire connection follows” on page 7 to correctly install the strain relief. DO NOT install the conduit without a strain relief. 2. Loosen the 2 lower left and right screws from the terminal block.
Part 4 INSTALL THE RANGE Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the three screws. Safety Glasses Tape Measure Use a spirit level to check your adjustments. Place the level diagonally on the oven rack, and check each Safety Glasses direction for level.
Page 11
To contact LG Electronics Para comunicarse con LG Electronics 24 hours a day, 7 days a week: 24 horas al día, 7 días a la semana: 1-800-243-0000 (USA) 1-800-243-0000 (EE.UU.) us.lge.com (USA) us.lge.com (EE.UU.) Or visit us on the Web at: O visítenos en la Web en:...