10.2.6 External Microphone input to Line out (balanced)

Noise level
Measure the noise, A-weighted & rms, at LINE-OUT via M119, related to M2 (GND):
Noise level (A-weighted): < -74 dBV.
90 ... 264V AC
X10
X110
LBB 3310/00, 3330/00 and 3331/00
4822 861 11006
~
~
Power Supply
AC
24V DC
PCB CPSU
Loudspeaker
(GND)
M110 M111
M121
M122 M124
6
9
4
8
2
Line-IN
Rec-IN
Rec-IN
L
X110
X205 M119
5
25Ω
M2
9
(GND)
(GND)
M150 M151
7
2
5
X150
Telephone
R
IN
Figure 4