Electrolux Smart Service Manual page 68

Boiling pan
Table of Contents

Advertisement

Electronic
(SM, SV, SP) from Rev. UCP 0419
Replacement of effect PCB
When replacing the effect PCB, the electronic shall be
adjusted for the correct size boiling pan as below:
· Press Menu forwards
taneously for 5 seconds.
· Digit the code 1991 by pressing Increase value
Decrease value
for digits, and Menu forwards
or Menu back
for the position.
· Confirm by pressing Start
PARAMETER SET-UP
·
Press Menu forwards
INITIATE PROGRAM
NO
YES
· Press Decrease value
· Press Menu forwards
· Confirm by pressing Start
The process will take a few minutes.
· Press Menu forwards
INITIATE DEFAULT
NO
YES
· Press Decrease value
· Press Menu forwards
· Confirm by pressing Start
· Press Menu forwards
SIZE
50
· Select boiling pan SIZE pressing Increase value
or Decrease value
· Press Menu forwards
AGITATOR
· Select VARIOMIX/PROMIX or WITHOUT AGITATOR
(Smart) pressing Increase value
lue
· Press Menu forwards
FOOD TEMP
· Select between YES or NO
· Press Menu forwards
(se fig.1)
and Menu back
simul-
.
for "YES"
for "YES"
or Decrease va-
INITIATE DEFAULT
NO
YES
· Press Decrease value
· Press Menu forwards
or
PULSE/ LITRE
· Select PULSE/ LITRE pressing Increase value
Decrease value
(Original flow sensor has 428 pulse/ litre)
· Press Menu forwards
AUTOMATIC COOLING
NO
YES
· Press Decrease value
· Press Menu forwards
If "YES" is chosen:
ICE WATER COOLING
NO
YES
· Press Decrease value
· Press Menu forwards
OPTION
· Select WITHOUT HACCP or WITH HACCP pressing
Increase value
LANGUAGE
· Select LANGUAGE pressing Increase value
crease value
· Press Menu forwards
o change the language, se even the section for Choice
of language at page 5.
PROGRAMMING
NO
YES
· Press Decrease value
· End the process by switching off the power, pressing
ON/OFF
.
Fuses:
there are 2 fuses on the effect PCB as follows:
F1= 400 mA Delay action fuse (5X20mm)
F2= 315 mA Delay action fuse (5X20mm)
for "YES"
for "YES"
for "YES"
or Decrease value
for "YES"
or
or De-
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents