Chapter 3
21
WebServer
UDP multicast streaming settings
Figure 14 illustrates streaming settings for a UDP multicast from the SymNet1 to the default multicast address.
The default multicast address is 230 for the first field and the balance being the unit's current IP address.
The SymDec-4 is set up as a receiver in Normal mode with the Receiver Cam Map IP address set at
192.168.10.20 (The IP address of the sender) and Use default multicast address checked. The SymNet1 is set
up as a sender with the mulitcast address set at 230.168.10.20. Once these settings are saved on their respective
web pages the SymNet1 will begin sending multicasting video (once requested) and the SymDec-4 will begin
receiving streaming video.
Figure 14. Sample UDP multicast settings
To use a multicast address other than the default, uncheck Use default multicast address on both web pages,
click the Advanced command in the mode drop-down menu and enter the same multicast address in the
Streaming address field.