Resetting Factory Settings; Decommissioning; Disposal Of Electronic Items; Disposal Of Lcd Display, Refrigerants, Lubricants And Oils - Bosch ACS 251 Original Instructions Manual

A/c service unit
Table of Contents

Advertisement

7.9

Resetting factory settings

Use this option to change the system default.
1. In the main menu, select "ACS Maintenance" >>
"Maintenance". Press E.
2. Select "Factory Settings". Press E
3. To revert to the settings to default settings done at
the factory, press .
4. Switch off and switch on.
"
The settings have been reset to factory settings.
Bosch Limited
Maintenance | ACS 251 | 21
8.

Decommissioning

8.1

Disposal of electronic items

This product is subject to European guidelines
2002/96/EG (WEEE).
Old electrical and electronic devices, including
cables and accessories or batteries must be
disposed of separate to household waste.
Please use the return and collection systems
in place for disposal in your area.
Damage to the environment and hazards to
personal health can be prevented by prop-
erly disposing of old equipment.
8.2
Disposal of LCD display, refrigerants,
lubricants and oils
Please dispose of the LCD display in accordance with
the local regulations for disposal of special waste.
Refrigerants that can no longer be used must be hand-
ed over to the gas suppliers for disposal.
The lubricants and oils recovered from the A/C systems
must be handed back to the designated return points.
8.3

Disposal of filter drier

Dispose the filter drier through the designated return
points or in accordance with local regulations.
8.4

Electromagnetic compatibility (EMC)

This product is compliant with EN 61000-6-2 and
EN61000-6-4 standards.
9.

Technical data

Property
Value/Range
Operating voltage
230 V ± 10 %
Frequency
50 / 60 Hz
Refrigerant
R134a
R134a scale
50 kg
LP manometer
-1 bar - 15 bar ± 1.6 % of final value
HP manometer
-1 bar - 34 bar ± 1.6 % of final value
Refrigerant tank capacity 12 l
Maximum system pres-
20 bar
sure PS
Pset
18 bar
Medium group
Group 2
Power
700 W
Permissible ambient tem-
10
perature TS
Optimum filling weight of
4 kg - 7 kg
R134a for operation
Dimensions (H x W x D)
1188 x 638 x 762
(mm)
Weight
90 kg
en
C - 50
C
O
O
|
F 002 DG9 425
2014-03-20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents