Available languages

Undesirable side effect
Thrombus
Injured tissue on nipple
(nipple trauma)

Storage conditions

Keep the breast pump out of direct sunlight as prolonged exposure may cause discoloration. Store the breast pump and
its accessories in a safe, clean and dry place.
If the device has been stored in a hot or cold environment, place it in an environment with a temperature of 20 °C (68 °F)
for 30 minutes to let it reach a temperature within the usage conditions (5 °C to 40 °C/41 °F to 104 °F) before you use it.

Electromagnetic fields (EMF)

This Philips device complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

Technical information

Vacuum level
Cycle speed
Motor unit rated input
Mains adapter rated input
Mains adapter rated output
Adapter type number
Power port
Operating conditions
Description
Thrombus can result into tenderness, pain, redness, swelling and/or heat.
-
Fissures or cracked nipples.
-
Skin tissue peeling off the nipple. Normally occurs in combination with cracked
nipples and/or blisters.
-
Nipple tear.
-
Blister. Looks like small bubbles on the surface of the skin.
-
Bleeding. Cracked or torn nipples can lead to bleeding of the affected area.
Single electric breast pump
Stimulation: -60 to -200 mbar (-45 to -150 mmHg)
Expression: -60 to -360 mbar (-45 to -270 mmHg)
Adjustable in steps of 20 mbar
Intermittent vacuum
Stimulation: 105-120 cycles/min, depending on vacuum level
Expression: 53-85 cycles/min, depending on vacuum level
5 V d.c. / 1.1 A
External mains adapter 100-240 V a.c.
50/60 Hz
400 mA
5 V d.c. / 1.1 A
S009AHz050yyyy The letters "yyyy" represent the output current from 0100
(1000 mA) to 0180 (1800 mA), increments in steps of 100 mA. The letter "z"
denotes type of plug, it can be: U, V, B, S, C, A, D, K, T, I, E, F.
Micro-USB
Temperature: 5 °C to 40 °C (41 °F to 104 °F)
Relative humidity: 15 to 90 % (non-condensing)
Double electric breast pump
5 V d.c. / 1.8 A
5 V d.c. / 1.8 A