• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.7 °CDB/19.4 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB/60 °FWB (21.1 °CDB/15.6 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.3 °CDB/6.1 °CWB).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: This value is "Cooling operation/Heating operation".
• *2: Sound pressure level:
–
Measured values in manufacturer's anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-11. Wall mounted type
Cooling
Heating
HIGH
MED
CFM (m
LOW
HIGH
MED
LOW
Length
Fin pitch
Rows × Stages
Face area
Pipe type (Material)
Type (Material)
Fin
Surface treatment
Type
Net material
Material
Color
Net
Gross
Net
Gross
Liquid (Flare)
Gas (Flare)
Drain hose
ASUA7TLAV
Btu/h
7,500
kW
2.2
Btu/h
9,500
kW
2.8
W
17
288 (490)
265 (450)
3
/h)
1
247/218*
1
(420/370*
)
W
35
33
dB (A)
1
31/27*
in (mm)
FPI
2
2
ft
(m
)
Antibacterial and mold proofing, ion deodorization
Approximate color of Munsell N9.25/
10-13/16 × 31-1/8 × 8-7/16 (275 × 790 × 215)
in (mm)
11-7/16 × 32-7/8 × 13-9/16 (290 × 835 × 345)
lb (kg)
in (mm)
I.D.: Ø 9/16 (13.8); O.D.: Ø 5/8 to 11/16 (15.8 to 16.7)