Turbo parts cleaning tank

Advertisement

3.
ASSEMBLY INSTRUCTIONS
Remove parts from packing and take items out of the tank. Before assembly check parts to ensure
they are complete and not damaged.
3.1.
Close lid (4) of tank (1), and turn unit upside down. Rest tank on a clean soft surface (i.e.
cardboard) ensuring lid is secured in the closed position.
3.2.
Attach the four legs (21) to the tank brackets with the pan head screws, spring washers and
hex nuts (22, 23, 24) but do not tighten.
3.3.
Place the lower shelf (20) between the four legs (21) with flat surface facing downward and
fix with washers, hex nuts and screws (22, 23, 24).
3.4.
With the legs pressed tightly against the lower shelf, tighten all the screws commencing with
those attaching the shelf.
3.5.
Hold the lid closed and stand the assembled unit upright. Open the lid but do not extend the
lid too far.
3.6.
Place the tank work shelf (42) on the two welded supports located inside the tank.
3.7.
Remove the self tapping screws from the cover plate of the pump unit (A) and check to
see if there is any supporting packing inside. If so, remove the supporting packing and
replace the cover.
3.8.
Place the pump into the tank unit and pass the switch unit through the slot in the cleaning
tank side (A). As the unit protrudes through the slot secure it by placing the underside lip
over the edge of the tank. Attach the flexible pipe (27) to pump (A).
3.9
To fit turbo valve assembly unscrew flexible tube (E), nut (D) and one nylon washer (C).
3.10.
Insert threaded end of turbo valve (B) through hole in side of tank and retain with washer
(C) and nut (D). Refit the flexible tube (E). Check that turbo valve (B) is closed.
4. OPERATING INSTRUCTIONS
! WARNING! Wear safety clothing, eye protection and gloves and ensure you read, under-
stand and apply the safety instructions in Section 1.
4.1.
Ensure the tank is located on a firm level surface in a well ventilated area and is switched
off and unplugged from the mains power supply.
4.2.
Fill the tank with Sealey solvent - approx. 50 litres. Minimum level must cover pump inlet -
approx. 40 litres. Follow the solvent instructions on the packaging.
4.3.
Plug the pump into the power supply and switch on. The cleaning agent will flow through
the flexible tube.
4.4.
Place parts to be washed into the basket, or directly into the tank. Direct solvent flow onto
parts. Heavily soiled items may be left to soak before cleaning.
4.5.
To improve cleaning and reduce pre-soak time turn on turbo valve to provide an agitating air
flow into the cleaning fluid.
4.6.
Do not leave the unit operating unattended. Check the fluid level does not fall below the
pump inlet.
4.7.
When cleaning is complete remove all parts whilst ensuring the minimum of cleaning agent
spillage.
4.8.
Switch off the pump, close the lid and disconnect from the mains power supply.
Clean up any spillage.
4.9.
Dispose of waste liquids in accordance with local authority regulations.
IMPORTANT! The SM20 has an anti-fire device built into the unit. In the event of a fire the lid will
automatically close. DO NOT prop the lid open as this will prevent the automatic safety
feature from operating. Once actuated, the fire detection device cannot be re-used and must
be replaced before further use.
# When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position
that would prevent the lid from closing fully if and when the fusible link activates.
5. MAINTENANCE
5. 1.
Clean the inside of the tank at regular intervals and keep the main body of the unit clean.
5. 2.
Regularly wash the pump filter in clean degreaser and replace if necessary.
5. 3.
Ensure that all screws and bolts are kept tight.
To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.
Turbo Parts Cleaning Tank
Model: SM20.V3
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
98/37/EC Machinery Directive
93/68/EEC CE Marking Directive
2002/95/EC RoHS Directive
2002/96/EC WEEE Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this equipment.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Parts support is available for this product.
Declaration of Conformity
in conformity with the following standards and directives.
Signed by Mark Sweetman
The construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to
contacting Jack Sealey Ltd.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
TANK ASSEMBLY
PUMP ASSEMBLY
We, the sole importer into the UK, declare that the product listed here is
1st June 2007
01284 757500
01284 703534
email
www.sealey.co.uk
Web
sales@sealey.co.uk
SM20.V3 - 1 - 110607

Advertisement

loading

This manual is also suitable for:

Power products sm20