A.1 Certificates & approvals
FM
The product meets the requirements of the standards:
• Factory Mutual Approval Standard Class Number 3611
• FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
A.1.2

Standards and test regulations

Industrial environments
The product was developed for use in industrial environments.
Application
Industry
Electromagnetic compatibility (EMC)
The electromagnetic compatibility (EMC) of an electrical device is its capability of functioning
as intended in an electromagnetic environment without emitting electromagnetic
interference that could impair the operation of other electrical devices in the vicinity.
Table A- 1
Electromagnetic compatibility
Immunity
EN 61000-4-2
Electrostatic discharge
EN 61000-4-3
Radiated electromagnetic field
EN 61000-4-4
Fast transient bursts
EN 61000-4-5
Surge immunity
EN 61000-4-6
Conducted disturbances
Noise emission
Conducted emissions
EN 61000-6-4, class A
0.15 MHz to 5 MHz
5 MHz to 30 MHz
Radiated emissions
EN 61000-6-4, class A
30 MHz to 230 MHz
230 MHz to 1 GHz
42
Requirements for emissions
EN 61000-6-4
8 kV air discharge to all surfaces
4 kV contact discharge to exposed conductive surfaces
80 ... 1 000 MHz, 10 V/m, 80% AM at 1 kHz
1.4 ... 2.0 GHz, 3 V/m, 80% AM at 1 kHz
2.0 ... 2.7 GHz, 1 V/m, 80% AM at 1 kHz
2 kV, 5 kHz with coupling network to AC and DC system power
1 kV, 5 kHz with coupling clamp to inputs/outputs
DC systems - 2 kV common mode, 1 kV push-pull
For DC systems (I/O signals, DC power supplies), external protection is
necessary.
150 kHz to 80 MHz, 10 V RMS, 80 % AM at 1 kHz
< 79 dB (μV) quasi peak; <66 dB (μV) average
< 73 dB (μV) quasi peak; <60 dB (μV) average
< 40 dB (μV/m) quasi peak; measured at 10 m
< 47 dB (μV/m) quasi peak; measured at a distance of 10 m
Requirements for immunity
EN 61000-6-2
Operating Instructions, 02/2021, C79000-G8976-C328-03