3.11 Multi-Function Interface (MFI)

A6V11164550
With release MP2.80 onward, SiPass integrated offers you the Multi-Function
Interface (MFI) that adds-on to the powerful functionality of the ACC-AP door
controller.
It can be added under ACC-AP (FLN 2 with
readers can be connected in different combinations, as required. See the
integrated Configuration Client User Guide
Alternatively, you can use the
Tools
located in the
folder in SiPass integrated software bundle.
Features:
Up to 4 MFI devices per ACC-AP can be connected, with up to 4 doors per MFI
(total of up to 16 doors per ACC-AP)
MFI I/O Only Mode: I/O device with 8 inputs and 8 outputs. Can be used for
general I/O, intrusion and low level-elevator control.
MFI Door Controller Mode: Secure OSDP V2 (encrypted) communication
between Door Reader and MFI
2 Door mode using up to 4 OSDP readers
4 Door mode using up to 8 OSDP readers
Support for global reader manufacturers
Support for mixed configuration with IPM, OPM, 8IO and IAT in the same FLN
bus
FLN Devices and Readers
Multi-Function Interface (MFI)
ACC FLN Bus