Download Print this page

LG PAHCMS000 Service Manual page 5

Hide thumbs Also See for PAHCMS000:

Advertisement

Safety Precautions
1.2 Inspections after Repair
Check to see if the terminal block is not dirty or loose. If terminal block is dust or
loose it can cause an electrical shock or fire.
Do not use a joined power cable or extension cable, or share the same power
outlet with other electrical appliances. otherwise, it can cause an electrical shock,
excessive heat generation or fire.
Do not insert hands or other objects through the air inlet or outlet while the
product is operating. There are sharp and moving parts that could cause
personal injury.
Do not block the inlet or outlet of air flow. It may cause product failure
Check to see if the parts are mounted correctly and wires are connected.
Improper installation and connections can cause an electric shock or an injury.
Check the installation platform or frame has corroded. Corroded installation
platform or frame can cause the unit to fall, resulting in injury.
Be sure to check the earth wire is correctly connected.
After the work has finished, be sure to do an insulation tset to check the
resistance is 2[Mohm] or more between the charge section and the non-charge
metal section (Earth position). If the resistance value is low, a disaster such as a
leak or electric shock is caused at user's side.
- 5 -

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Pahcmr000