Chapter 2 Useful Features
Assert NMI on SERR
FRB-2 Policy
Boot Monitoring
Boot Monitoring Policy
Thermal Sensor
Check previous System Config
BMC IRQ
(Express5800/T110f-E)
Post Error Pause
Memory Error
Power Switch Inhibit
CLI SETUP
Option
Disabled
[Enabled]
[Retry 3 Times]
Disable FRB2 Timer
Always Reset
[Disabled]
5-60 minutes
[Retry 3 times]
Always Reset
Disabled
[Enabled]
[Disabled]
Enabled
[Disabled]
IRQ 11
Disabled
[Enabled]
Halt
[Boot]
[Disabled]
Enabled
[Disabled]
Enabled
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
Parameter
Enables or disables the feature to detect PCI
SERR.
Specifies how to operate when FRB level 2
errors occur.
Enables or disables the boot monitoring
feature and specifies the timeout setting.
To use this feature, install NEC ESMPRO
Agent on Windows. If starting up an OS on
which it is not installed, disable this feature.
Specifies the processing to be done when
time-out was enforced during boot
monitoring. This is configurable only if Boot
Monitoring has been enabled.
Retry 3 times resets the server upon the
timeout and attempts to boot OS up to three
times.
Always Reset retries booting the OS
repeatedly.
Enables or disables the thermal sensor
monitoring. If this option is set to Enabled
and when abnormal temperature is detected,
the system stops at the end of POST.
If this option is set to Enabled and the
system configuration differs from the
previous boot, the system waits for user's
intervention before booting.
Specifies whether to assign an interrupt line
to the BMC.
Specifies whether to stop the POST once at
the end of POST if an error occurs during the
POST.
Specifies whether to stop operation at the
end of POST processing if a memory
resource error occurred while executing
POST.
This option is enabled if POST Error Pause
in the Server menu is enabled.
Even if this option is set to Boot, operation
stops at the end of POST if errors occurred
for all resources.
Enables or disables the power switch inhibit
feature.
Specifies whether to use Command Line
Interface (CLI).
Enabled : SETUP is run by CLI instead of
the menu operation. To switch back to the
meu operation, set this option to Disabled on
CLI.
1. System BIOS
(2/2)
Description
77