Pioneer PE6000 Series User Manual page 82

Table of Contents

Advertisement

Description of Function Codes
Function
Parameter Name
Code
Frequency source
P0-07
It is used to select the frequency setting channel. If the frequency source involves X and Y
operation, you can set the frequency offset in P0-21 for superposition to the X and Y operation
result, flexibly satisfying various requirements.
Frequency setting based on main frequency source X and auxiliary frequency source Y
Frequency source
selection
Main frequency
source X
Auxiliary
frequency
source Y
Function
Parameter Name
Code
P0-08
Preset frequency
If the frequency source is digital setting or terminal UP/DOWN, the value of this parameter is
the initial frequency of the AC drive (digital setting).
Ten's digit (X and Y operation relationship)
0: X+Y
1: X-Y
selection
2: Maximum
3: Minimum
4. X×Y
Frequency source X and
Y operation selection
P0-07 ten's digit
Setting Range
Setting of operation
conditions
P0-07 unit's digit
Setting Range
0.00 to maximum frequency (valid when
frequency source is digital setting)
82
PE6000 User Manual
Default
0
Target running
frequency
Set frequency
Default
50 Hz