  • Page 1 User’s Manual ACQ550-CC Packaged Drive with Bypass Supplement for ACQ550-U1 Drives User’s Manual...
  • Page 2 Supplement to ACQ550-U1 User’s Manual • Safety • Installation • Start-Up • Technical Data ACQ550-CC Packaged Drive with Bypass Supplement for ACQ550-U1 User’s Manual • Safety • Installation • Start-Up • Maintenance • Technical Data © 2007 ABB Inc. All Rights Reserved.
  • Page 3 ACQ550 with Bypass is connected to the line. Disconnect and lock out power to the drive before servicing the drive. Failure to disconnect power may cause serious injury or death. Note! For more technical information, contact the factory or your local ABB sales representative. Safety...
  • Page 4: Safety

    ACQ550-CC Packaged Drive with Bypass Use of Warnings and Notes There are two types of safety instructions throughout this manual: • Notes draw attention to a particular condition or fact, or give information on a subject. • Warnings caution you about conditions which can result in serious injury or death and/or damage to the equipment.
  • Page 5: Table Of Contents

    ACQ550-CC Packaged Drive with Bypass Table of Contents Safety Use of Warnings and Notes ........2 Table of Contents Installation Application .
  • Page 6: Installation

    ACQ550-CC Packaged Drive with Bypass Installation Study these installation instructions carefully before proceeding. Failure to observe the warnings and instructions may cause a malfunction or personal hazard. WARNING! Before you begin read “Safety” on page 1. WARNING! When the ACQ550 with Bypass is connected to the line power, the Motor Terminals T1, T2, and T3 are live even if the motor is not running.
  • Page 7 ACQ550-CC Packaged Drive with Bypass The following shows the front view of a typical ACQ550 Bypass wall mount configuration, and identifies the major components. ACQ-CP-AQ Control Panel Operating handle for Circuit Breaker Cover Control The following shows the front view of a typical ACQ550 Bypass floor mount configuration, and identifies the major components.
  • Page 8: Installation Flow Chart

    ACQ550-CC Packaged Drive with Bypass The following is a typical power diagram. Drive with Bypass Drive Output Circuit Breaker Contactor 3 Phase ACQ550 Motor Input Power Drive Service Switch Bypass (Optional) Contactor Installation Flow Chart The installation of Bypass Configurations for ACQ550 drives follows the outline below.
  • Page 9: Preparing For Installation

    ACQ550-CC Packaged Drive with Bypass Preparing for Installation Lifting the Drive Floor Mounting Warning! Handle and ship floor mounted enclosures only in the upright position. These units are not designed to be laid on their backs. 1. Use a pallet truck to move the package/enclosure to the installation site.
  • Page 10: Preparing For Installation

    ACQ550-CC Packaged Drive with Bypass Preparing for Installation Drive Identification To identify the type of device you are installing, refer to the type code number on the device identification label. • Wall mounting base drives – label attached on the side surface of the heat sink. •...
  • Page 11: Installing The Drive

    ACQ550-CC Packaged Drive with Bypass Installing the Drive Warning! Metal shavings or debris in the enclosure can damage electrical equipment and create a hazardous condition. Where parts, such as conduit plates require cutting or drilling, first remove the part. If that is not practical, cover nearby electrical components to protect them from all shavings or debris.
  • Page 12: Installing The Wiring

    ACQ550-CC Packaged Drive with Bypass Installing the Wiring WARNING! • Metal shavings or debris in the enclosure can damage electrical equipment and create a hazardous condition. Where parts, such as conduit plates require cutting or drilling, first remove the part. If that is not practical, cover nearby electrical components to protect them from all shavings or debris.
  • Page 13 ACQ550-CC Packaged Drive with Bypass Wiring Overview Connection Diagrams — ACQ550-CC units are configured for wiring access from the top or the bottom. The following figures show the wiring connection points. Refer to the ACQ550-U1 User's Manual for control connections to the drive. Typical Wall Mount Typical Floor Mount Control Transformer...
  • Page 14 ACQ550-CC Packaged Drive with Bypass Install the Line Input Wiring Line Input Connections – Bypass Configurations Connect input power to the terminals of the circuit breaker. Connect the equipment grounding conductor to the ground lug at the top of the enclosure. The figures below show the connection points for typical configurations.
  • Page 15 ACQ550-CC Packaged Drive with Bypass Install the Motor Wiring Motor Connections – Bypass Configurations Connect the motor cables to the motor overload relay output terminals; see the figures below. The motor grounding conductor can be connected to the ground lug near the motor overload relay.
  • Page 16 ACQ550-CC Packaged Drive with Bypass Terminal Block 1TB MOTOR RUN REMOTE RUN Replace Jumper with customer run enable interlock contacts Connection Points Basic control connections are made to 1TB, which is a din-rail terminal block on the back panel at the bottom of the enclosure. 1TB includes screw clamp terminals rated for #22-10 AWG stranded or solid wire.
  • Page 17 ACQ550-CC Packaged Drive with Bypass Auto Start Contact To start the ACQ550 by means of an external un-powered contact (maintained), connect the contact to 1TB:9 and 1TB:10. Closing this contact will start the motor when the drive is in the AUTO mode. Relay Contact Output A “Motor Running”...
  • Page 18 ACQ550-CC Packaged Drive with Bypass Motor Overload Relay The ACQ550 with Bypass includes a motor overload relay to provide thermal motor protection. It is connected in both drive and bypass modes of operation. For motor full load currents up to 80 amperes, the Motor Overload Relay is an adjustable trip, bimetallic overload relay with a class 20 trip characteristic.
  • Page 19: Maintenance

    Maintenance Interval If installed in an appropriate environment, the drive requires very little maintenance. The table lists the routine maintenance intervals recommended by ABB. The information shown below is supplemental and in addition to that shown in the ACQ550-U1 User’s Manual.
  • Page 20: Technical Data

    ACQ550-CC Packaged Drive with Bypass Technical Data Ratings Note! The ratings listed below are exceptions to the ratings listed in the ACQ550-U1 User’s Manual. Ratings, 380…480 Volt Drives Type Code Valid up to 40°C (104 °F) Normal Use Heavy-Duty Use Frame Size ACQ550-Cx- see below...
  • Page 21 ACQ550-CC Packaged Drive with Bypass 208…240 Volt Fuses 208/240 Volt Drive Input Fuse Ratings Frame Amps Bussmann Size Identification (600V) Type ACQ550-CC-04A6-2 KTK-R-15 ACQ550-CC-06A6-2 KTK-R-15 ACQ550-CC-07A5-2 KTK-R-15 ACQ550-CC-012A-2 KTK-R-15 ACQ550-CC-017A-2 KTK-R-30 ACQ550-CC-024A-2 KTK-R-30 ACQ550-CC-031A-2 JJS-50 ACQ550-CC-046A-2 JJS-80 ACQ550-CC-059A-2 JJS-80 ACQ550-CC-075A-2 JJS-100 ACQ550-CC-088A-2 JJS-110...
  • Page 22 ACQ550-CC Packaged Drive with Bypass 380…480 Volt Fuses 380…480 Volt Drive Input Fuse Ratings Frame Amps Bussmann Size Identification (600V) Type 1/1.5 ACQ550-CC-03A3-4 KTK-R-15 ACQ550-CC-04A1-4 KTK-R-15 ACQ550-CC-06A9-4 KTK-R-15 ACQ550-CC-08A8-4 KTK-R-15 ACQ550-CC-012A-4 KTK-R-15 ACQ550-CC-015A-4 KTK-R-30 ACQ550-CC-023A-4 KTK-R-30 ACQ550-CC-031A-4 JJS-50 ACQ550-CC-038A-4 JJS-50 ACQ550-CC-045A-4 JJS-100 ACQ550-CC-059A-4...
  • Page 23 ACQ550-CC Packaged Drive with Bypass Fuses, 500…600 Volt, Fuses 500…600 Volt Drive Input Fuse Ratings Frame Amps Bussmann Size Identification (600V) Type ACQ550-CC-02A7-6 KTK-R-15 ACQ550-CC-03A9-6 KTK-R-15 ACQ550-CC-06A1-6 KTK-R-15 ACQ550-CC-09A0-6 KTK-R-15 ACQ550-CC-011A-6 KTK-R-30 ACQ550-CC-017A-6 KTK-R-30 ACQ550-CC-022A-6 JJS-50 ACQ550-CC-027A-6 JJS-50 ACQ550-CC-032A-6 JJS-100 ACQ550-CC-041A-6 JJS-100 ACQ550-CC-052A-6...
  • Page 24: Power Connection Terminals

    ACQ550-CC Packaged Drive with Bypass Power Connection Terminals The following tables show maximum wire size and required tightening torque for incoming power, motor, and grounding terminals. 208…240 Volt, Terminals 208…240 Volt, Power Connection Terminal Data 208/240 Volt Base Power Wiring Size Drive Ground Lugs Circuit...
  • Page 25 ACQ550-CC Packaged Drive with Bypass 340…480 Volt, Terminals 340…480 Volt, Power Connection Terminal Data 340…480 Volt Base Power Wiring Size Drive Ground Lugs Circuit Overload Frame Type Code Breaker Relay Size 1/1.5 ACQ550-CC-03A3-4 ACQ550-CC-04A1-4 ACQ550-CC-06A9-4 ACQ550-CC-08A8-4 62 in-lbs 22 in-lbs ACQ550-CC-012A-4 ACQ550-CC-015A-4 15 in-lbs...
  • Page 26 ACQ550-CC Packaged Drive with Bypass 500…600 Volt, Terminals 500…600 Volt, Power Connection Terminal Data 500…600 Volt Base Power Wiring Size Drive Ground Lugs Circuit Overload Frame Type Code Breaker Relay Size ACQ550-CC-02A7-6 ACQ550-CC-03A9-6 ACQ550-CC-06A1-6 62 in-lbs ACQ550-CC-09A0-6 22 in-lbs ACQ550-CC-011A-6 15 in-lbs ACQ550-CC-017A-6 (#14 - #12)
  • Page 27: Motor Connections

    ACQ550-CC Packaged Drive with Bypass Motor Connections Motor Terminals See preceding “Power Connection Terminal Data” tables. Bypass Contactors The bypass circuit in the ACQ550 Bypass includes two contactors. One contactor is the bypass contactor (2M) that can be used to connect the motor directly to the incoming power line in the event that the ACQ550 is out of service.
  • Page 28: Motor Connection Specifications - R8

    ACQ550-CC Packaged Drive with Bypass Motor Connection Specifications – R8 Motor Connection Specifications Max. Motor Cable Length* Frame Size Maximum Motor Cable = 1 or 4 kHz = 8 kHz or 12 kHz Length 300 m 980 ft Does not apply * Warning! Using a motor cable longer than specified in the chart above may cause permanent damage to the drive.
  • Page 29: Dimensions And Weights

    ACQ550-CC Packaged Drive with Bypass Dimensions and Weights Dimensional References The following tables contain dimensional references that will be needed to identify the dimensional information applying to a given type code. 208/230V Bypass Packages UL Type / UL Type / UL Type / Type Code Frame...
  • Page 30 ACQ550-CC Packaged Drive with Bypass 480V Bypass Packages UL Type / UL Type / UL Type / Type Code Frame NEMA 1 NEMA 12 NEMA 3R Dim. Ref. Page 29 Dim. Ref. Page 30 Dim. Ref. Page 31 ACQ550-CC-03A3-4 CX1-1 CX12-1 CX3R-1 ACQ550-CC-03A3-4...
  • Page 31 ACQ550-CC Packaged Drive with Bypass Dimensions: ACQ550-CC NEMA 1 R1 through R8 Frame Size CX1-1 to CX1-11 Wall Mounted CX1-12 to CX1-13 Free Standing Height (H) Width (W) Depth (D) Weight CX1-1 [36.2] [8.2] [37.3] [13.7] [13.7] [76] CX1-2 [36.2] [8.2] [37.3] [13.7]...
  • Page 32 ACQ550-CC Packaged Drive with Bypass Dimensions: ACQ550-CC NEMA 12 R1 through R8 Frame Size CX12-1 to CX12-10 Wall Mounted CX12-11 to CX12-12 Free Standing Height (H) Width (W) Depth (D) Weight CX12-1 [25.5] [16.5] [27] [18] [14.5] [78] CX12-2 [25.5] [16.5] [27] [18]...
  • Page 33 ACQ550-CC Packaged Drive with Bypass Dimensions: ACQ550-CC NEMA 3R R1 through R6 Frame Size CX3R-1 to CX3R-9 Wall Mounted CX3R-10 Free Standing Width Width Height (H) Width (W) Depth (D) Weight (W2) (W3) CX3R-1 [22.5] [16.5] [24] [18] [3.5] [14.1] [82] CX3R-2 [22.5]...
  • Page 34: Applicable Standards

    ACQ550-CC Packaged Drive with Bypass Applicable Standards Drive compliance with the following standards is identified by the standards “marks” on the type code label. Mark Applicable Standards UL 508C and UL Standard for Safety, Power Conversion Equipment, and C22.2 No. 14 CSA Standard for Industrial Control Equipment UL 508A UL Standard for Safety, Industrial Control Panels...
  • Page 35: Index

    ACQ550-CC Packaged Drive with Bypass Index Numerics 208…230V bypass packages ....27 Floor mount installing the line input wiring ... . . 12 380…480V bypass packages .
  • Page 36 ACQ550-CC Packaged Drive with Bypass NEMA 1 Technical data ......18–32 code ....... . 8 Terminal block 1TB.
  • Page 37 ACQ550-CC Packaged Drive with Bypass Index...