Environmental Conditions; Transport And Storage Conditions; Operating Conditions - Siemens SIMATIC IFP2200 Product Information

Industrial monitors
Hide thumbs Also See for SIMATIC IFP2200:
Table of Contents

Advertisement

Available languages

Available languages

Environmental conditions

Transport and storage conditions

Mechanical and climatic conditions for transportation and storage
The transportation and storage conditions of this device exceed requirements in accordance with IEC 60721-3-2. The
following information is for a device that is transported and stored in its original packaging.
Type of condition
Drop test (in transport package)
Temperature
Atmospheric pressure
Relative humidity
Sinusoidal vibration in accordance with
IEC 60068-2-6
Shock in accordance with IEC 60068-2-27
Proper transport and storage, installation and assembly as well as careful operation and maintenance are prerequisites for
trouble-free and safe operation of the device.
Non-compliance will render the warranty for the device null and void.

Operating conditions

Mechanical and climatic conditions of use
The device is designed for use in locations protected from the effects of the weather. The conditions of use meet the
requirements for DIN IEC 60721-3-3:
Class 3M3 (mechanical requirements)
Class 3K3 (climatic requirements)
Use with additional measures
The device should not be used at the following locations unless additional measures are taken:
In locations with a high degree of ionizing radiation
In locations with severe operating conditions, for example, due to:
Corrosive vapors, gases, oils or chemicals
Electrical or magnetic fields of high intensity
In systems that require special monitoring - for example:
Elevators
Systems in especially hazardous rooms
Mechanical ambient conditions
The mechanical ambient conditions for the device are specified in the table below in terms of sinusoidal vibration.
Device type
IFP devices
ITC devices
SIMATIC IFP2200/2400 ITC2200/2400 frameless
A5E48015893-AB, 10/2020
Permitted range
≤ 1 m
–20 to +60 °C
1080 to 660 hPa, corresponds to an elevation of –1000 to 3500 m
10% to 90%, without condensation
5 to 8.4 Hz, deflection 3.5 mm
25 g, 6 ms, 1000 shocks
Frequency range f in Hz
10 Hz ≤ f ≤ 58 Hz (0.0375 mm)
58 Hz ≤ f ≤ 200 Hz (4.9 m/s
5 Hz ≤ f ≤ 8.4 Hz (3.5 mm)
8.4 Hz ≤ f ≤ 200 Hz (9.8 m/s
Comment
Mechanical class 2
)
see table below
2
Mechanical class 3
)
see table below
2
8.4 to 500 Hz, acceleration 1 g
25