8.1.1.1.4 Connection to the system
At first appearance of the set, the system creates the configuration file associated to this set and
automatically declares the set in the system subscribers' list.
The set sends an HTTPS request to retrieve its configuration files.
Note:
The SIP parameter configuration file is named <MAC address>.xml
Example:
00809f5607ae.xml
The set being plug&phone, it starts automatically and can be used straight away.
The set can be further configured in OMC. It is visible in the subscribers list as SIP Phone (8001) or
SIP Phone (8001G).
8.1.1.1.5 Manual (static) configuration
The set IP parameters can be modified after first initialization.
On the set itself, connected to the system:
1. Press the OK button, or the Menu softkey
2. Go to System settings > Advanced settings > Advanced
3. Select Network > LAN Port
4. Select the Static mode
5. Configure the set IP address, ensuring first that it is a free address
6. Configure other IP parameters: IP subnetwork mask, and gateway (that is router)
7. Configure DNS settings
8. Configure port management settings
9. Go to System settings > Advanced settings > Advanced > Auto Provision
Enter the URL: https://<OXO Connect_IP_address>:10443/dmcfg and select HTTPS as
protocol
10.Press the Save softkey
Important:
If the OXO Connect is installed and configured in a VLAN topology, the VLAN must be manually enabled in
the advanced settings of the set. The corresponding OXO Connect VLAN Value must be entered manually
in set configuration.
8.1.1.1.6 Upgrading set binaries
If requested:
1. In OMC, select Import/Export > File Management For third Party Devices
2. Import the binary files and firmware configuration files in the directory named: Binary
3. Reboot the set manually
When the set connects to the OXO Connect, it upgrades its software, provided the binaries
imported in the system and the binaries present in the set are of a different version.
Note:
Set binaries can be imported or deleted, but not exported
8.1.1.1.7 Replacing the set by another 8001/8001G Deskphone set
In case of a replacement by another 8001/8001G Deskphone set, modify the MAC address of the set in
OMC.
There is no backup of terminal data, which means that the local call log and saved contacts are lost.