Pulling on drive output elements
● Requirements:
– The coupling and/or the drive output element must be appropriately dimensioned for
– Observe the coupling manufacturer's instructions.
– Make sure that the balancing type of the drive output element correctly matches the
– Use only ready drilled and balanced drive output elements. Check the hole diameters
● Pulling on:
– Heat up the drive output elements to expand them before pulling them on. Select the
– Drive output elements may only be pulled on or pulled off with the correct equipment.
– Do not use a hammer, as this will damage the bearings.
Only transfer radial or axial forces specified in the catalog to the motor bearings via the shaft
extension.
You can obtain the permissible values for axial and radial forces by contacting the Service
Center (Page 159) or by referring to the machine catalog.
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 06/2020, A5E44455710A
the operating case at hand.
type of balance of the rotor.
and the balancing status before pulling them on. Thoroughly clean the shaft extension.
temperature difference for the heating process to suit the coupling diameter, fit and
material. Observe the coupling manufacturer's instructions.
The drive output element must be pulled on in one continuous operation via the front
thread holes in the shaft or pushed on by hand.
Withdrawing drive output elements
Mounting drive output elements
Assembly
5.5 Installing the machine