Connecting to a Computer
Control from a computer in the same subnet group
Device Group
DME Satellite
(IP address: 192.168.0.3)
(Master ID: 7)
NO T E
• The IP addresses in the diagram are examples.
• Use a switching hub that is compatible with 100Base-TX/10Base-T network speeds.
The maximum length of a cable between a switching hub and the DME Satellite is 100 meters. Due to the quality of cables
and switching hub performance, however, proper operation at the maximum length cannot be guaranteed in some cases.
Use a STP (Shielded Twisted Pair) cable to prevent electromagnetic interference.
• If you are using multiple DME series units, set Link Mode on each unit to the same setting. Yamaha recommends that you
select 100Base-TX for the Link Mode setting.
• You can also connect a supported controller such as the AMX or Crestron, and control the DME Satellite remotely. For
details, refer to "Connecting to an External Device" on page 26.
Group Master
DME Satellite (IP address: 192.168.0.7)
Ethernet Cable
Switching Hub
Ethernet Cable
Ethernet
Straight Cable
DME64N/24N
(IP address: 192.168.0.250)
(Master ID: 7)
Ethernet Straight Cable
SCENE
SCENE
HOME
HOME
UTILITY
UTILITY
LEVEL
LEVEL
MUTE
MUTE
CANCEL
CANCEL
ENTER
ENTER
DME8i-ES/DME8o-ES/DME4io-ES Owner's Manual
Computer
(IP address:
192.168.0.100)