Parameter list (FR-A800)
Param-
Name
eter
Torque control P gain 1
824
(current loop
proportional gain)
Torque control integral
825
time 1 (current loop
integral time)
826
Torque setting filter 1
827
Torque detection filter 1
828
Model speed control gain
830
Speed control P gain 2
Speed control integral
831
time 2
832
Speed setting filter 2
833
Speed detection filter 2
834
Torque control P gain 2
Torque control integral
835
time 2
836
Torque setting filter 2
837
Torque detection filter 2
840
Torque bias selection
841
Torque bias 1
842
Torque bias 2
843
Torque bias 3
844
Torque bias filter
Torque bias operation
845
time
Torque bias balance
846
compensation
Fall-time torque bias
847
terminal 1 bias
Fall-time torque bias
848
terminal 1 gain
Analog input offset
849
adjustment
850
Brake operation selection
853
Speed deviation time
854
Excitation ratio
Terminal 4 function
858
assignment
Torque current/Rated PM
859
motor current
Second motor torque
860
current/Rated PM motor
current
864
Torque detection
865
Low speed detection
A - 12
Setting Range
Initial Value
0–500 %
100 %
0–500 ms
5 ms
0–5 s, 9999
9999
0–0.1 s
0 s
0–1000 %
60 %
0–1000 %,9999
9999
0–20 s, 9999
9999
0–5 s, 9999
9999
0–0.1 s, 9999
9999
0–500 %, 9999
9999
0–500 ms, 9999
9999
0–5 s, 9999
9999
0–0.1 s, 9999
9999
0–3, 24, 25, 9999
9999
600–1400 %,
9999
9999
600–1400 %,
9999
9999
600–1400 %,
9999
9999
0–5 s, 9999
9999
0–5 s, 9999
9999
0–10 V, 9999
9999
0–400 %, 9999
9999
0–400 %, 9999
9999
0–200 %
100 %
0–2
0
0–100 s
1 s
0–100 %
100 %
0, 1, 4, 9999
0
0–500 A, 9999
0–3600 A,
9999
9999
0–500 A, 9999
0–3600 A,
9999
9999
0–400 %
150 %
0–590 Hz
1.5 Hz
Param-
Name
eter
Torque monitoring
866
reference
867
AM output filter
Terminal 1 function
868
assignment
869
Current output filter
Speed detection
870
hysteresis
Input phase loss
872
protection selection
873
Speed limit
874
OLT level setting
875
Fault definition
Speed feed forward
877
control/model adaptive
speed control selection
878
Speed feed forward filter
Speed feed forward
879
torque limit
880
Load inertia ratio
881
Speed feed forward gain
Regeneration avoidance
882
operation selection
Regeneration avoidance
883
operation level
Regeneration avoidance
884
at deceleration detection
sensitivity
Regeneration avoidance
885
compensation frequency
limit value
Regeneration avoidance
886
voltage gain
888
Free parameter 1
889
Free parameter 2
Cumulative power
891
monitor digit shifted
times
892
Load factor
Energy saving monitor
893
reference (motor
capacity)
Control selection during
894
commercial power-
supply operation
Power saving rate
895
reference value
896
Power unit cost
Power saving monitor
897
average time
Power saving cumulative
898
monitor clear
Operation time rate
899
(estimated value)
FM/CA terminal
C0
(900)
calibration
C1
AM terminal calibration
(901)
Appendix
Setting Range
Initial Value
0–400 %
150 %
0–5 s
0.01 s
0–6, 9999
0
0–5 s
0.02 s
0–5 Hz
0 Hz
0, 1
0
0–400 Hz
20 Hz
0–400 %
150 %
0, 1
0
0–2
0
0–1 s
0 s
0–400 %
150 %
0–200 times
7 times
0–1000 %
0 %
0–2
0
380 V DC/
300–800 V
760 V DC
0–5
0
0–590 Hz, 9999
6 Hz
0–200 %
100 %
0–9999
9999
0–9999
9999
0–4, 9999
9999
30–150 %
100 %
Rated
0.1–55 kW
/
inverter
0–3600 kW
capacity
0–3
0
0, 1, 9999
9999
0–500, 9999
9999
0, 1–1000 h, 9999
9999
0, 1, 10, 9999
9999
0–100 %, 9999
9999