command CHDNRS;
-
Assign IBSC `3, 1 kHz audio' (IBSC=2) to the DNRs of the ALC using OM command
CHDNRS;
-
Assign the correct Terminal Endpoint Identifier to the SOPHO-LAMs used (TEI=0 or
TEI=1; first or second B-channel respectively). For programming the TEI value refer to
the Customer Engineer Manual of the SOPHO-LAM P375.
-
Define a group of convertors for either outgoing traffic (DLC/DTX side) or incoming
traffic (ALC side) using OM command CRGRPA. Use the following parameter settings:
GROUP-PROPS:
- empty group allowed
- group hunting
- hunting sequence
- automatic COB
- call pickup
- pickup to group only
- observation group
- ACD
GROUP-DISPLAY=0;
SUPERVISOR-DNR and PARK-POS are not applied;
-
Download the CV information towards the SOPHO-LAM using OM command
DOWNLD;
-
Ensure that the convertor modem clears the connection when the state of CT108 changes
from ON to OFF.
You can set this option using Hayes command AT&D2;
-
CT107 indicates the condition of the analogue line (normal operation according to V.24
specifications).
This means the following:
-
CT107 is OFF in the idle state;
-
CT107 goes OFF when the Hang Up process is started;
-
CT107 goes ON as soon as the connection set-up is started;
-
CT107 goes ON in the V.25(bis) dialog mode.
You can set this operation using Hayes command AT&S1;
-
For a convertor pool for incoming calls, set the convertor modems in the `silent' mode
(no strings send to the SOPHO-LAM).
You can set this option using Hayes command ATQ1;
-
For a convertor pool for incoming calls, set the convertor modem in the automatic
answering mode using Hayes command ATS0=1;
-
For a convertor pool for outgoing calls, set the convertor modems in the `non-silent'
mode (send strings to the SOPHO-LAM).
42
= no;
= yes;
= fixed or cyclic;
= yes or no;
= no;
= no;
= no;
= no.

Advertisement

loading

This manual is also suitable for:

Sopho ssw 810