DODGE
200 and 300 Series Direct Mount Plummer Blocks
These instructions must be read thoroughly before installation or operation. This instruction manual was accurate at the time of
printing. Please see baldor.com for updated instruction manuals.
Note! The manufacturer of these products, Baldor Electric Company, became ABB Motors and Mechanical Inc. on
March 1, 2018. Nameplates, Declaration of Conformity and other collateral material may contain the company name of
Baldor Electric Company and the brand names of Baldor-Dodge and Baldor-Reliance until such time as all materials have
been updated to reflect our new corporate identity.
WARNING: To ensure the drive is not unexpectedly
started, turn off and lock-out or tag power source before
proceeding. Failure to observe these precautions could
result in bodily injury.
WARNING: All products over 25 kg (55 lbs) are noted on the
shipping package. Proper lifting practices are required for
these products.
WARNING: Because of the possible danger to person(s)
or property from accidents which may result from the
improper use of products, it is important that correct
procedures be followed. Products must be used in
accordance with the engineering information specified
in the catalog. Proper installation, maintenance and
operation procedures must be observed. The instructions
in the instruction manuals must be followed. Inspections
should be made as necessary to assure safe operation
under prevailing conditions. Proper guards and other
suitable safety devices or procedures as may be desirable
or as may be specified in safety codes should be provided,
and are neither provided by ABB nor are the responsibility
of ABB. This unit and its associated equipment must be
installed, adjusted and maintained by qualified personnel
who are familiar with the construction and operation of
all equipment in the system and the potential hazards
involved. When risk to persons or property may be
involved, a holding device must be an integral part of the
driven equipment beyond the speed reducer output shaft.
USN 500 and 600 Series Adapter Mount &
®
GENERAL INFORMATION
Dodge USN bearings conform with all appropriate ISO
standards. They are available in either adapter or direct
mounting styles for 40 mm to 160 mm diameter shafts. A wide
variety of seals are available including standard metallic LER,
TRIPLE-TECT™ non-metallic seal with V-ring, Drop-in TRIPLE-
TECT seal with neoprene V-ring, Auxiliary Taconite or Split
non-metallic. TRIPLE-TECT seal is provided as standard on
complete assemblies. DODGE USN housings provide you with
maximum application flexibility. Cast-in dimples allow for easy
field modification for vents, lube ports and sensors. Oversized
drains and an oil equalization hole make USN bearings ready for
circulating oil systems off-the-shelf. For hostile environments,
USN offers optional cast closed end housings, stainless
steel hardware kits, and nickel or nylon coating. Complete
installation, maintenance and modification instructions are
provided in this manual.
INSPECTION
Inspect shaft — Ensure that the shaft is smooth, straight,
clean, and within commercial tolerances.
Inspect bearing — Do not allow bearing to be exposed to any
dirt or moisture. Do not remove preservative compound as it
acts as both a protectant and lubricant and is also compatible
with standard greases.
Note: Housing caps and bases are not interchangeable.
They must be matched with mating half. Install non-
expansion bearing first.
Note: For seal types other than TRIPLE-TECT such as drop-
in TRIPLE-TECT, LER, auxiliary seals and split seals follow
instructions supplied with the seals.
Note: For an explanation of the various dimples and tapped
holes found on the USN housings, see Table 11.
1

Advertisement

loading

Summary of Contents for ABB DODGE USN 500 Series

  • Page 1 Please see baldor.com for updated instruction manuals. Note! The manufacturer of these products, Baldor Electric Company, became ABB Motors and Mechanical Inc. on March 1, 2018. Nameplates, Declaration of Conformity and other collateral material may contain the company name of Baldor Electric Company and the brand names of Baldor-Dodge and Baldor-Reliance until such time as all materials have been updated to reflect our new corporate identity.
  • Page 2: Installation

    INSTALLATION: Now find a lockwasher tab that aligns with a locknut slot and bend tab into slot. If slot is past tab then tighten, not loosen, USN 500 and 600 Series Adapter Mount locknut to meet a washer tab. Apply a coating of light oil or other rust inhibitor to the Steps f and g are not necessary if pillow block housing is a adapter area of the shaft.
  • Page 3 INSTALLATION: Table 3 - Radial Clearance of 222 Series Spherical USN 200 and 300 Series Direct Mount Roller Bearings (Straight Bore) C3 Radial Clearance (mm) Basic Bearing No. Measure the internal clearance of the bearing before Min. Max. mounting. Place the bearing in an upright position as 22209 .055 .075...
  • Page 4 Table 4 - Shaft Diameters For Cylindrical Bore Mount Plummer Blocks (See Figure 2) Normal Load High Load Bearing Bore (mm) Shaft Diameter (mm) Mean Shaft Diameter (mm) Mean (mm) Nom. Max. Min. Max. Min. Max. Min. 40.000 39.988 40.025 40.009 .023 40.033...
  • Page 5: Maintenance

    Table 5 - Tolerance Table 6 - Shaft Diameter, S-2 (See Figure 2) Shaft Diameter (S-2) (mm) Bearing Bore Diameter (mm) S-2 (mm) Over Including Tolerance 35 mm 100 mm +.000 to -.102 100 mm 150 mm +.000 to -.127 Over 150 mm +.000 to -.152 d.
  • Page 6 90-100 intervals. For special applications involving high speeds or high 110-130 temperatures consult your local ABB Motors and Mechanical 140-160 representative for MPT products. Applications such as conveyor pulleys and fans are shipped Table 9 - Maximum RPM (Adapter Mount) to a job site with bearings already mounted to the shafts.
  • Page 7 Removal of excess grease must be done in a clean, protected environment. For circulating oil, the flow rate and size of return drains are shown in Table 12. Consult application engineering for ABB MPT products for recommendations.
  • Page 8 Table 10 - Maximum RPM (Direct Mount) Maximum RPM Shaft Size, Basic Bearing (mm) Description Grease 22308 C3 4300 5300 22209 C3 5600 7000 22310 C3 3400 4300 22211 C3 4500 5600 22212 C3 4000 5000 22213 C3 3600 4500 22314 C3 2400 3200...
  • Page 9 Table 11 - USN Plummer Block— Dowel Pin, Lubrication & Mounting Hole Position G Max. USN Series Dia. Hole Size Bolt Size 21.5 510/608/308 22.5 511/609/309 25.5 512/212/ 25.5 610/310 513/611/311 32.5 515/215/ 47.5 612/312 516/216/ 51.5 613/313 517/217/314 52.5 37.5 10.5 518/218/...
  • Page 10 Table 12 - USN Circulating Oil Chart Circulating Oil Flow* Static Oil Maximum Amount For Block Amount Sufficient For Level (mm) Heat Dissipation Due to Drain Holes Size Normal Lubrication External Heat Source Size (BSPP) Liters/Min. Liters/Min. .009 26.5 1/8-28 .011 .341 1/8-28...
  • Page 16 ABB Motors and Mechanical Inc. 5711 R. S. Boreham Jr. Street Fort Smith, AR 72901 Ph: 1.479.646.4711 Mechanical Power Transmission Support Ph: 1.864.297.4800 new.abb.com/mechanical-power-transmission baldor.com © ABB Motors and Mechanical Inc. All Rights Reserved. Printed in USA. MN3066 (Replaces 499801 & 499809) 11/19...