Signal
Function
name
SLS4S
SLS4 output
SSMS
SSM output
SBC monitor output
*2
SBCS
*1
The value "0" or "1" in the parentheses is the bit value.
*2
The signal is used for monitoring. It is not used for controlling the brake.
18
4. I/O Signals for Safety Sub-Functions
4.1 I/O signal list
OFF (1): SLS4 function enabled.
ON (0): SLS4 function disabled.
OFF (0): The motor speed (output frequency) is higher than the SSM frequency.
ON (1): The motor speed (output frequency) is equal to or lower than the SSM
frequency.
OFF (1): The brake is applied.
ON (0): The brake is released.
*1
Description
Refer to
page
24
27
29