Bosch DSDA ISCSI DISK ARRAY SERIES DSA-N2B20 Installation Manual page 31

Dsda iscsi disk array series
Hide thumbs Also See for DSDA ISCSI DISK ARRAY SERIES DSA-N2B20:
Table of Contents

Advertisement

DSDA iSCSI Disk Array Series
1.
2.
3.
4.
Bosch Security Systems
Upload the new software to a Web server
If you are using VRM, place the file that contains the new version in
C:\Program Files\Bosch\Video Recording Manager\VRM Server\web
on your VRM Server.
If you are not using VRM, start a Web server tool, for example MiniWebServer.exe,
select a root directory and copy the new software version into this root directory.
Example screen:
Download and install the new version on the storage controller hard disks:
Connect to the console of the storage device. To connect to the console, select Filer >
Use Command Line in the navigation panel of the FilerView administration interface.
If you are using VRM:
On the console, enter
software install http://username:password@<VRM Server IP>/
<Filename>
Replace <username> and <password> with the login information of your VRM server.
Replace <VRM Server IP> with the IP address of your VRM server and <Filename>
with the name of the file that contains the new version.
Wait a few minutes for the installation to complete.
If you are using MiniWebServer.exe:
On the console, enter software install http://<MiniWebServer>/<filename> and
replace <filename> with the name of the software update file.
Wait until the success message displays: Installation of setup.exe-7.xxx_e.exe
completed.
Download the new software to the CF card:
On the console, enter: download.
Wait until the success message displays: Operator requested download completed.
On the console, enter: halt.
The system reboots and stops at the bootloader.
Note that no data can be written on the disks while the system is rebooting.
Installation Guide
Monitoring and Maintenance | en
V 1 | 2008.08
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsa-n2b50Dsa-s5b50

Table of Contents