Connection Method - NEC UNIVERGE SV8300 Pc Programming Manual

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

Description
Required for the PC
(PCPro)
* Customer purchases

Connection method

STEP1: Using PCPro (IP connection), set the following system data on the SV8300:
• CM0B YYY=0XX/1XX (XX:01-50[Unit number])
First data
Second data : aaa.bbb.ccc.ddd (example 10.40.221.9)*
* aaa: 000 - 255 bbb: 000 - 255 ccc: 000-255 ddd: 000 -254
• CM0B YYY=0XX/1XX (XX:01-50[Unit number])
First data
Second data : aaa.bbb.ccc.ddd (Subnet mask)*
* aaa: 000 - 255 bbb: 000 - 255 ccc: 000-255 ddd: 000 -252
• CM0B YYY=0XX/1XX (XX:01-50[Unit number])
First data
Second data : aaa.bbb.ccc.ddd (Default gateway)*
* aaa: 000 - 255 bbb: 000 - 255 ccc: 000-255 ddd: 000 -254
NOTE 1:
CAT mode can not be used when an IP address, Subnet mask and Default gateway are as-
signed by CM0B.
NOTE 2:
Period (.) is required when an IP address, Subnet mask and Default gateway are assigned
by CM0B (Example: 10.40.221.9).
Quantity
LAN cable*
Up to 2
PC*
Up to 2
: 00 (IP address of the System)
: 01 (System subnet mask)
: 02 (System default gateway)
• 10BASE-T/100BASE-TX LAN cable
(STP category 5 [cross/straight cable])
• For the specifications of the PC
required, see "Operating Environ-
ments and Connections"
1-3
2-7
Chapter 2 Setting Up PCPro
Connecting PCPro to the SV8300
Remarks
Page
NWA-033628-001 Rev.1.0