11.5 Miscellaneous
11.5.1 Test of Charger
Manual test without CST can also be carried
out with the help of the text below.
Test with CST check of signal with charger
connected.
1
CCU A:4 is an input signal indicating that the bat-
tery charger is connected. In the connector mount-
ed on the battery charger cable is a strap between
pins 3 and 4. In the connector mounted on the
machine, +5 V is connected to pin 3 orange lead
and to pin 4, a green lead is connected to CCU.
2
Connect a battery charger to the machine. Activate
the machine and measure the green lead at A4. It
should read +5 V if OK.
If there is no voltage on the green lead on connec-
tor A, measure the connector for engaging the bat-
tery charger on the machine so that there is +5 V
on the orange lead's connector, checking also that
the green lead is attached.
CST Autotest
Miscelaneous
Charger
Connector A at CCU
A4: Charger in
Common point
Common point
Battery charger connector
GND
GND
113