M.-Nr. 07485101
A
Aktiver gennemløbsmålingen for det pågældende flowmeter (her fx nummer 1) for styringen via servicemodus, se
TSD'en.
A
Foretag funktionskontrol med et vaskeprogram, hvor der løber vand ind i maskinen via flowmeteret.
da
en-US
Flow meter installation instructions
Reason: The flow meter is used to measure the water coming into the machine.
Parts included
Quantity Mat. no.
Designation
1
Flow meter
1
Water intake adapter
2
Seal, 3/4" 16 x 23.8 x 1.5
1
White sticker, 99 x 1 x 38.1
1
Various cable holders, 98 x 2.5
1
M12 x 1.5 cord connector
1
Reducing coupler, 1" inner diameter x 3/4" inner diameter, brass
1
Pipe nipple, 3/4" outer diameter
1
Adapter, 1" outer diameter x 3/4" inner diameter, brass
1
Wiring diagram, multifunction module 7 (flow meter)
Danger due to incorrectly carried out service and repair work
WARNING
Danger due to incorrectly carried out service and repair work.
There is a risk of serious damage, injury and even death if service and repair work is carried out incorrectly.
A
Service and repair work should only be carried out by a suitably qualified electrician with specialist training,
knowledge and experience.
A
All appropriate safety regulations must be taken into account.
A
Read the technical service documentation (TSD) before starting service work.
Risk of cuts
CAUTION
Components are sharp.
Risk of cuts.
A
Protective gloves should be worn and the edge protection, mat. no. 05057680, should be used.
Flow meter installation
The flow meter can only be installed if multifunction module 7 (flow meter) has already been installed in the machine.
During installation, the adapter must be installed as a damper between the shutoff valve and flow meter. Take note of
the arrow marked on the flow meter showing the correct direction of flow. Use the correct seals appropriate for the
pipe diameter only. In this way water can flow freely without added turbulence through the measuring area. Correct
flow measurement can only be achieved if these instructions are complied with.