Connecting The Cables - Bosch AEC‑AMC2‑UL01 Installation Manual

Amc2 enclosure with 1 din rail
Hide thumbs Also See for AEC‑AMC2‑UL01:
Table of Contents

Advertisement

AMC2 enclosure with 1
DIN rail
3.2

Connecting the cables

Notice!
See chapter Cable assembly, page 21 for a list of UL
approved/listed cables and UL authorized suppliers.
Connecting the AMC2 power cable (A)
1.
2.
3.
4.
Connecting the AC power cable (F)
1.
2.
3.
Figure 3.2: Connections of the LED indicator
Bosch Security Systems B.V.
Connect the 7-pin plug A7 (Figure 4.1) to the power supply
connector (label: POWER) of the AMC2.
Attach connector A8 (Figure 4.1) to the power supply
connection labeled OK.
Attach connector A9 (Figure 4.1) to the power supply
connection DC.
Connect the grounding cable A6 (Figure 4.1) to the AMC2
grounding point.
Use the cables to connect the three-pin connector (Figure
1.1, position 11) to the AC connector (Figure 4.6, position
F4) of the power supply.
Connect the blue wire to the port marked with N (Figure
3.2, positions 2 and 4).
Connect the brown wire to the port marked with L (Figure
3.2, positions 1 and 3).
AC
BAT
RTH
L N
+ -
N G
L1
Connections | en
2020-07 | V04 | F.01U.330.018